Technical Specifications
Parameters and characteristics for this part
| Specification | AMEL20-5SMAZ |
|---|---|
| Applications | ITE (Commercial), Medical |
| Approval Agency | cURus, CB, CE, cULus, IEC, UL, EN |
| Current - Output (Max) [Max] | 4 A |
| Efficiency | 77 % |
| Features | Universal Input |
| Line Regulation | 1 % |
| Load Regulation | 2 % |
| Mounting Type | Through Hole |
| Number of Outputs | 1 |
| Package / Case | 5-DIP Module, 4 Leads |
| Power (Watts) | 20 W |
| Size / Dimension [x] | 56.5 mm |
| Size / Dimension [x] | 2.22 " |
| Size / Dimension [y] | 1.21 in |
| Size / Dimension [y] | 30.9 mm |
| Size / Dimension [z] | 25.1 mm |
| Size / Dimension [z] | 0.99 " |
| Standard Number | 60601-1 |
| Type | Enclosed |
| Voltage - Input [Max] | 264 VAC, 370 VDC |
| Voltage - Input [Min] | 130 VDC, 90 VAC |
| Voltage - Output 1 | 5 V |
| Weight [custom] | 0.154 lb |
| Weight [custom] | 70 g |
| Part | Line Regulation | Approval Agency | Standard Number | Weight [custom] | Weight [custom] | Load Regulation | Voltage - Output 1 | Power (Watts) | Operating Temperature [Min] | Operating Temperature [Max] | Size / Dimension [y] | Size / Dimension [z] | Size / Dimension [x] | Size / Dimension [y] | Size / Dimension [x] | Size / Dimension [z] | Efficiency | Voltage - Input [Min] | Voltage - Input [Max] | Mounting Type | Applications | Package / Case | Number of Outputs | Current - Output (Max) [Max] | Type | Weight [custom] | Weight [custom] | Load Regulation | Features | Weight | Weight |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
aimtec | 0.5 % | CE cURus EN IEC UL | 60335-1 60601-1 61558-1 62368-1 | 55 g | 0.121 lb | ±1% | 9 V | 20 W | -40 °C | 85 °C | 1.07 in | 0.94 " | 2.06 " | 27.2 mm | 52.4 mm | 24 mm | 85 % | 85 VAC 100 V | 305 VAC 430 VDC | Through Hole | Household Appliances ITE (Commercial) Medical | 6-DIP Module 4 Leads | 1 | 2.2 A | Enclosed | ||||||
aimtec | 1 % | CB CE cULus cURus EN IEC UL | 60601-1 | 5 V | 20 W | 1.21 in | 0.99 " | 2.22 " | 30.9 mm | 56.5 mm | 25.1 mm | 77 % | 90 VAC 130 VDC | 264 VAC 370 VDC | Through Hole | ITE (Commercial) Medical | 5-DIP Module 4 Leads | 1 | 4 A | Enclosed | 0.154 lb | 70 g | 2 % | Universal Input | |||||||
aimtec | 1 % | CB CE cULus cURus EN IEC UL | 60601-1 | 24 V | 20 W | 1.21 in | 0.99 " | 2.22 " | 30.9 mm | 56.5 mm | 25.1 mm | 79 % | 90 VAC 130 VDC | 264 VAC 370 VDC | Through Hole | ITE (Commercial) Medical | 5-DIP Module 4 Leads | 1 | 840 mA | Enclosed | 0.154 lb | 70 g | 2 % | Universal Input | |||||||
aimtec | 1 % | CB CE cURus EN FCC IEC UL | 60950-1 | 5 V | 20 W | -40 °C | 80 ¯C | 1.21 in | 0.99 " | 2.22 " | 30.9 mm | 56.5 mm | 25.1 mm | 74 % | 90 VAC 130 VDC | 305 VAC 430 VDC | Through Hole | ITE (Commercial) | 5-DIP Module 4 Leads | 1 | 4 A | Enclosed | 0.154 lb | 70 g | 2 % | ||||||
aimtec | 1 % | CB CE cURus FCC | ±1% | 15 V | 20 W | -40 °C | 80 ¯C | 1.21 in | 0.99 " | 2.22 " | 30.9 mm | 56.5 mm | 25.1 mm | 80 % | 90 VAC | 305 VAC | Through Hole | ITE (Commercial) | 5-DIP Module 4 Leads | 1 | 1.33 A | Enclosed | 0.154 lb | 70 g | |||||||
aimtec | 0.5 % | CE cURus EN IEC UL | 60335-1 60601-1 61558-1 62368-1 | 55 g | 0.121 lb | ±1% | 12 V | 20 W | -40 °C | 85 °C | 1.07 in | 0.94 " | 2.06 " | 27.2 mm | 52.4 mm | 24 mm | 86 % | 85 VAC 100 V | 305 VAC 430 VDC | Through Hole | Household Appliances ITE (Commercial) Medical | 6-DIP Module 4 Leads | 1 | 1.67 A | Enclosed | DC Input Capable Universal Input | |||||
aimtec | 0.5 % | CE UL | 60335-1 60601-1 62368-1 | 55 g | 0.121 lb | ±1% | 12 V | 20 W | -40 °C | 85 °C | 1.07 in | 0.94 " | 2.06 " | 27.2 mm | 52.4 mm | 24 mm | 86 % | 85 VAC 100 V | 305 VAC 430 VDC | Through Hole | Household Appliances ITE (Commercial) Medical | 6-DIP Module 4 Leads | 1 | 1.67 A | Enclosed | ||||||
aimtec | 0.5 % | ±1% | 9 V | -25 °C | 70 °C | 1.13 " | 0.93 " | 2.12 in | 28.8 mm | 53.8 mm | 23.5 mm | 85 VAC 100 V | 264 VAC 370 VDC | Through Hole | ITE (Commercial) | 4-DIP Module | 1 | Enclosed | Universal Input | 60 g | 0.132 lb | ||||||||||
aimtec | 1 % | CB CE cURus EN FCC IEC UL | 60950-1 | ±1% | 12 V | 20 W | -40 °C | 80 ¯C | 1.21 in | 0.99 " | 2.22 " | 30.9 mm | 56.5 mm | 25.1 mm | 80 % | 90 VAC | 305 VAC | Through Hole | ITE (Commercial) | 5-DIP Module 4 Leads | 1 | 1.66 A | Enclosed | 0.154 lb | 70 g | ||||||
aimtec | 1 % | CB CE cURus | ±1% | 12 V | 20 W | 1.21 in | 0.99 " | 2.22 " | 30.5 mm | 56.5 mm | 25.1 mm | 80 % | 90 VAC | 264 VAC | Through Hole | ITE (Commercial) Medical | 5-DIP Module 4 Leads | 1 | 1.66 A | Enclosed | 0.154 lb | 70 g | Universal Input |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
| Distributor | Package | Quantity | $ | |
|---|---|---|---|---|
| Digikey | N/A | 0 | $ 55.05 | |
| Tube | 1 | $ 39.85 | ||
| 7 | $ 39.45 | |||
| 14 | $ 39.06 | |||
| 28 | $ 38.67 | |||
| 56 | $ 38.28 | |||
| 112 | $ 37.90 | |||
| 224 | $ 37.52 | |||
| 448 | $ 37.14 | |||
Description
General part information
AMEL20 Series
Enclosed AC DC Converters 1 Output 5V 4A 90 ~ 264 VAC, 130 ~ 370 VDC Input
Documents
Technical documentation and resources