L
LITTELFUSE
| Series | Category | # Parts | Status | Description |
|---|---|---|---|---|
| Part | Spec A | Spec B | Spec C | Spec D | Description |
|---|---|---|---|---|---|
| Series | Category | # Parts | Status | Description |
|---|---|---|---|---|
| Part | Spec A | Spec B | Spec C | Spec D | Description |
|---|---|---|---|---|---|
| Part | Category | Description |
|---|---|---|
LITTELFUSE DRR-DTH-Q2167-2Obsolete | Switches | SWITCH REED CUSTOM |
LITTELFUSE DRR-DTH-70-85Obsolete | Switches | SWITCH REED SPDT 350MA 350V |
LITTELFUSE | Switches | ROCKER SWITCHES |
LITTELFUSE | Switches | SWITCH PUSHBUTTON DPDT 6A 250V |
LITTELFUSE 0HEV040.ZXPCBLObsolete | Circuit Protection | FUSE - HEV LC 425VDC 40A, PCB 3.9MM TERM/ BULK |
LITTELFUSE 0324015.HObsolete | Circuit Protection | FUSE CERM 15A 250VAC 125VDC 3AB |
LITTELFUSE NANOSMD200LR-2Obsolete | Circuit Protection | PTC RESET FUSE 6V 2A 1206 |
LITTELFUSE | Connectors Interconnects | LINEAR IC'S |
LITTELFUSE | Circuit Protection | TVS 1.5KW 36V 5%BI DO-214AB TR13 |
LITTELFUSE | Connectors Interconnects | LINEAR IC'S |
| Series | Category | # Parts | Status | Description |
|---|---|---|---|---|
PLR240A3 PHASE LINE MONITOR | Relay Output Monitors | 1 | Active | The PLR Series provides a cost effective means of preventing 3-phase motor startup during adverse voltage conditions. Proper A-B-C sequence must occur in order for the PLR’s output contacts to energize. In addition, the relay will not energize when an undervoltage or phase loss condition is present. The PLR protects a motor against undervoltage operation. The adjustment knob sets the undervoltage trip point. Operation The output relay is energized and the LED glows when all voltages are acceptable and the phase sequence is correct. Undervoltage must be sensed for a continuous dropout delay period before the relay de-energizes. Reset is automatic upon correction of the fault condition. The output relay will not energize if a fault condition is sensed as power is applied. |
PLR380A3 PHASE LINE MONITOR | Monitors | 1 | Active | The PLR Series provides a cost effective means of preventing 3-phase motor startup during adverse voltage conditions. Proper A-B-C sequence must occur in order for the PLR’s output contacts to energize. In addition, the relay will not energize when an undervoltage or phase loss condition is present. The PLR protects a motor against undervoltage operation. The adjustment knob sets the undervoltage trip point. Operation The output relay is energized and the LED glows when all voltages are acceptable and the phase sequence is correct. Undervoltage must be sensed for a continuous dropout delay period before the relay de-energizes. Reset is automatic upon correction of the fault condition. The output relay will not energize if a fault condition is sensed as power is applied. |
PLR480A3 PHASE LINE MONITOR | Monitors | 1 | Active | The PLR Series provides a cost effective means of preventing 3-phase motor startup during adverse voltage conditions. Proper A-B-C sequence must occur in order for the PLR’s output contacts to energize. In addition, the relay will not energize when an undervoltage or phase loss condition is present. The PLR protects a motor against undervoltage operation. The adjustment knob sets the undervoltage trip point. Operation The output relay is energized and the LED glows when all voltages are acceptable and the phase sequence is correct. Undervoltage must be sensed for a continuous dropout delay period before the relay de-energizes. Reset is automatic upon correction of the fault condition. The output relay will not energize if a fault condition is sensed as power is applied. |
| Monitors | 1 | Active | ||
PLS120AREVERSE PHASE RELAY | Industrial Automation and Controls | 1 | Active | The PLS Series is a low cost phase sensitive control that provides an isolated contact closure when the proper A-B-C phase sequence is applied. Protects sensitive 3-phase equipment and equipment operators from reverse rotation. Designed to be compatible with motor overloads or other 3-phase equipment protection devices. Protection for equipment control centers where frequent reconnection or electrical code makes reverse rotation protection essential. Examples include: mobile refrigerated containers, construction equipment, hoists, pumps, conveyors, elevators and escalators. Operation The internal relay and LED are energized when the phase sequence is correct. The output relay will not energize if the phases are reversed. Reset is automatic upon correction of the fault. |
PLS240AREVERSE PHASE RELAY | Relay Output Monitors | 1 | Active | The PLS Series is a low cost phase sensitive control that provides an isolated contact closure when the proper A-B-C phase sequence is applied. Protects sensitive 3-phase equipment and equipment operators from reverse rotation. Designed to be compatible with motor overloads or other 3-phase equipment protection devices. Protection for equipment control centers where frequent reconnection or electrical code makes reverse rotation protection essential. Examples include: mobile refrigerated containers, construction equipment, hoists, pumps, conveyors, elevators and escalators. Operation The internal relay and LED are energized when the phase sequence is correct. The output relay will not energize if the phases are reversed. Reset is automatic upon correction of the fault. |
| Keylock Switches | 1 | Obsolete | ||
PM1204ZERO CROSS OPTCALLY ISO SCR 0.5 AMP 400V | Relays | 2 | Active | The OptoMOS® line of power products uses dual power SCR outputs to produce an alternative to optocoupler and Triac circuits. These switches provide a blocking voltage of up to 800V. In addition, tightly controlled zero-cross circuitry ensures switching of AC loads without the generation of transients. The input and output circuits are optically coupled to provide up to 5000Vrms of isolation and noise immunity between control and load circuits. Long life and environmental integrity make these power switches ideal for controlling a variety of AC circuits in industrial environments where electromagnetic interference would disrupt the operation of electromechanical relays. |
PM1205ZERO CROSS OPTCALLY ISO SCR 0.5 AMP 500V | Solid State Relays (SSR) | 2 | Active | The OptoMOS® line of power products uses dual power SCR outputs to produce an alternative to optocoupler and Triac circuits. These switches provide a blocking voltage of up to 800V. In addition, tightly controlled zero-cross circuitry ensures switching of AC loads without the generation of transients. The input and output circuits are optically coupled to provide up to 5000Vrms of isolation and noise immunity between control and load circuits. Long life and environmental integrity make these power switches ideal for controlling a variety of AC circuits in industrial environments where electromagnetic interference would disrupt the operation of electromechanical relays. |
PM1206ZERO CROSS OPTCALLY ISO SCR 0.5 AMP 600V | Solid State Relays (SSR) | 5 | Active | The OptoMOS® line of power products uses dual power SCR outputs to produce an alternative to optocoupler and Triac circuits. These switches provide a blocking voltage of up to 800V. In addition, tightly controlled zero-cross circuitry ensures switching of AC loads without the generation of transients. The input and output circuits are optically coupled to provide up to 5000Vrms of isolation and noise immunity between control and load circuits. Long life and environmental integrity make these power switches ideal for controlling a variety of AC circuits in industrial environments where electromagnetic interference would disrupt the operation of electromechanical relays. |