Zenode.ai Logo
Beta
No image
Sensors, Transducers

TMCS1126C2AQDVGR

Active
Texas Instruments

80ARMS 500KHZ HALL-EFFECT CURRENT SENSOR WITH AFR, REFERENCE AND ALERT

Sensors, Transducers

TMCS1126C2AQDVGR

Active
Texas Instruments

80ARMS 500KHZ HALL-EFFECT CURRENT SENSOR WITH AFR, REFERENCE AND ALERT

Technical Specifications

Parameters and characteristics for this part

SpecificationTMCS1126C2AQDVGR
Current - Sensing [Max]91.4 A
Current - Sensing [Min]-4.6 A
Current - Supply (Max) [Max]80 A
For MeasuringAC/DC
Frequency [Max]550 kHz
Frequency [Min]DC
Linearity0.1 %
Mounting TypeSurface Mount
Number of Channels1
Operating Temperature [Max]125 °C
Operating Temperature [Min]-40 °C
OutputVoltage, Ratiometric
Package / Case10-SOIC
PolarizationBidirectional
Response Time250 ns
Sensitivity50 mV/A
Sensor TypeHall Effect
Supplier Device Package10-SOIC
Voltage - Supply [Max]5.5 V
Voltage - Supply [Min]3 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyTape & Reel (TR) 2000$ 2.69
Texas InstrumentsLARGE T&R 1$ 3.43
100$ 3.01
250$ 2.11
1000$ 1.70

Description

General part information

TMCS1126 Series

The TMCS1126 is a galvanically isolated Hall-effect current sensor with industry leading isolation and accuracy. An output voltage proportional to the input current is provided with excellent linearity and low drift at all sensitivity options. Precision signal conditioning circuitry with built-in drift compensation is capable of less than 1.4% maximum sensitivity error over temperature and lifetime with no system level calibration, or less than 1% maximum sensitivity error including both lifetime and temperature drift with a one-time calibration at room temperature.

AC or DC input current flows through an internal conductor generating a magnetic field measured by integrated, on-chip, Hall-effect sensors. Core-less construction eliminates the need for magnetic concentrators. Differential Hall sensors reject interference from stray external magnetic fields. Low conductor resistance increases measurable current ranges up to ±103A while minimizing power loss and easing thermal dissipation requirements. Insulation capable of withstanding 5kVRMS, coupled with a minimum of 8mm creepage and clearance, provides high levels of reliable lifetime reinforced working voltage. Integrated shielding enables excellent common-mode rejection and transient immunity.

Fixed sensitivity allows the device to operate from a single 3V to 5.5V power supply, eliminating ratiometry errors and improving supply noise rejection. TI provides the TMCS1126xxB as a lower-cost option.