16 SSOP
Integrated Circuits (ICs)

74HC191DB,118

Obsolete
Freescale Semiconductor - NXP

IC BINARY COUNTER 4-BIT 16SSOP

Deep-Dive with AI

Search across all available documentation for this part.

DocumentsDatasheet
16 SSOP
Integrated Circuits (ICs)

74HC191DB,118

Obsolete
Freescale Semiconductor - NXP

IC BINARY COUNTER 4-BIT 16SSOP

Deep-Dive with AI

DocumentsDatasheet

Technical Specifications

Parameters and characteristics for this part

Specification74HC191DB,118
Count Rate39 MHz
DirectionUp, Down
Logic TypeBinary Counter
Mounting TypeSurface Mount
Number of Bits per Element4
Number of Elements1
Operating Temperature [Max]125 °C
Operating Temperature [Min]-40 °C
Package / Case16-SSOP
Package / Case [custom]0.209 in
Package / Case [custom]5.3 mm
ResetAsynchronous
Supplier Device Package16-SSOP
TimingSynchronous
Trigger TypePositive Edge
Voltage - Supply [Max]6 V
Voltage - Supply [Min]2 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$

Description

General part information

74HC191D Series

The 74HC191 is an asynchronously presettable 4-bit binary up/down counter. It contains four master/slave flip-flops with internal gating and steering logic to provide asynchronous preset and synchronous count-up and count-down operation. Asynchronous parallel load capability permits the counter to be preset to any desired value. Information present on the parallel data inputs (D0 to D3) is loaded into the counter and appears on the outputs when the parallel load (PL) input is LOW. This operation overrides the counting function. Counting is inhibited by a HIGH level on the count enable (CE) input. WhenCEis LOW internal state changes are initiated synchronously by the LOW-to-HIGH transition of the clock input. The up/down (U/D) input signal determines the direction of counting as indicated in the function table. TheCEinput may go LOW when the clock is in either state, however, the LOW-to-HIGHCEtransition must occur only when the clock is HIGH. Also, theU/D input should be changed only when eitherCEor CP is HIGH. Overflow/underflow indications are provided by two types of outputs, the terminal count (TC) and ripple clock (RC). The TC output is normally LOW and goes HIGH when a circuit reaches zero in the count-down mode or reaches '15' in the count-up-mode. The TC output will remain HIGH until a state change occurs, either by counting or presetting, or untilU/D is changed. Do not use the TC output as a clock signal because it is subject to decoding spikes. The TC signal is used internally to enable theRCoutput. When TC is HIGH andCEis LOW, theRCoutput follows the clock pulse (CP). This feature simplifies the design of multistage counters as shown in Figure 1 and Figure 2. In Figure 1, eachRCoutput is used as the clock input to the next higher stage. It is only necessary to inhibit the first stage to prevent counting in all stages, since a HIGH onCEinhibits theRCoutput pulse. The timing skew between state changes in the first and last stages is represented by the cumulative delay of the clock as it ripples through the preceding stages. This can be a disadvantage of this configuration in some applications. Figure 2 shows a method of causing state changes to occur simultaneously in all stages. TheRCoutputs propagate the carry/borrow signals in ripple fashion and all clock inputs are driven in parallel. In this configuration the duration of the clock LOW state must be long enough to allow the negative-going edge of the carry/borrow signal to ripple through to the last stage before the clock goes HIGH. Since theRCoutput of any package goes HIGH shortly after its CP input goes HIGH there is no such restriction on the HIGH-state duration of the clock. In Figure 3, the configuration shown avoids ripple delays and their associated restrictions. Combining the TC signals from all the preceding stages forms theCEinput for a given stage. An enable must be included in each carry gate in order to inhibit counting. The TC output of a given stage it not affected by its ownCEsignal therefore the simple inhibit scheme of Figure 1 and Figure 2 does not apply. Inputs include clamp diodes. This enables the use of current limiting resistors to interface inputs to voltages in excess of VCC.