AD597ARZ
ActiveTYPE K THERMOCOUPLE CONDITIONER AND SETPOINT CONTROLLER
Deep-Dive with AI
Search across all available documentation for this part.

AD597ARZ
ActiveTYPE K THERMOCOUPLE CONDITIONER AND SETPOINT CONTROLLER
Technical Specifications
Parameters and characteristics for this part
| Specification | AD597ARZ |
|---|---|
| Accuracy | 4 °C |
| Function | Thermocouple Conditioner |
| Mounting Type | Surface Mount |
| Operating Temperature [Max] | 125 °C |
| Operating Temperature [Min] | -55 °C |
| Output Alarm | True |
| Output Fan | False |
| Package / Case | 8-SOIC |
| Package / Case [x] | 0.154 in |
| Package / Case [y] | 3.9 mm |
| Sensing Temperature [Max] | 1250 °C |
| Sensing Temperature [Min] | -200 °C |
| Sensor Type | External |
| Supplier Device Package | 8-SOIC |
| Topology | Ice Point Compensation |
| Voltage - Supply [Max] | 30 VDC |
| Voltage - Supply [Min] | 5 V |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
| Distributor | Package | Quantity | $ | |
|---|---|---|---|---|
| Digikey | Tube | 1 | $ 13.47 | |
| 10 | $ 9.54 | |||
| 25 | $ 8.53 | |||
| 100 | $ 7.40 | |||
| 250 | $ 6.85 | |||
| 500 | $ 6.52 | |||
| 1000 | $ 6.33 | |||
Description
General part information
AD597 Series
The AD596/AD597 is a monolithic temperature setpoint controller which has been optimized for use at elevated temperatures such as those found in oven control applications. The device cold junction compensates and amplifies a type J or K thermocouple input to derive an internal signal proportional to temperature. The internal signal is then compared with an externally applied setpoint voltage to yield a low impedance switched output voltage. Dead-Band or switching hysteresis can be programmed using a single external resistor. Alternately, the AD596/ AD597 can be configured to provide a voltage output (10 mV/°C) directly from a type J or K thermocouple signal. It can also be used as a stand-alone voltage output temperature sensor.The AD596/AD597 can be powered with a single supply from +5 V to +30 V, or dual supplies up to a total span of 36 V. Typical quiescent supply current is 160 µA which minimizes self-heating errors.The AD596/AD597 H package option includes a thermocouple failure alarm that indicates an open thermocouple lead when operated in the temperature proportional measurement mode. The alarm output has a flexible format which can be used to drive relays, LEDs or TTL logic.The device is packaged in a reliability qualified, cost effective 10-pin metal can, 8-pin plastic mini-DIP or SOIC and is trimmed to operate over an ambient temperature range from +25°C to +100°C. Operation over an extended ambient temperature range is possible with slightly reduced accuracy. The AD596 will amplify thermocouple signals covering the entire -200°C to +760°C temperature range recommended for type J thermocouples while the AD597 can accommodate -200°C to +1250°C type K inputs.The AD596/AD597 has a calibration accuracy of ±4°C at an ambient temperature of 60°C and an ambient temperature stability specification of 0.05°C/°C from +25°C to +100°C. If higher accuracy, or a lower ambient operating temperature is required, either the AD594 (J thermocouple) or AD595 (K thermocouple) should be considered.