STMICROELECTRONICS STEF12EPUR
Integrated Circuits (ICs)

STEF12EPUR

Active
STMicroelectronics

ELECTRONIC FUSE, 18V, -40 TO 125DEG C ROHS COMPLIANT: YES

Deep-Dive with AI

Search across all available documentation for this part.

STMICROELECTRONICS STEF12EPUR
Integrated Circuits (ICs)

STEF12EPUR

Active
STMicroelectronics

ELECTRONIC FUSE, 18V, -40 TO 125DEG C ROHS COMPLIANT: YES

Deep-Dive with AI

Technical Specifications

Parameters and characteristics for this part

SpecificationSTEF12EPUR
FunctionElectronic Fuse
Mounting TypeSurface Mount
Operating Temperature [Max]125 °C
Operating Temperature [Min]-40 C
Package / Case10-VFDFN Exposed Pad
Supplier Device Package10-DFN (3x3)
Voltage - Input [Max]18 V
Voltage - Input [Min]7.6 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyCut Tape (CT) 1$ 1.26
10$ 1.13
25$ 1.07
100$ 0.88
250$ 0.82
500$ 0.73
1000$ 0.57
Digi-Reel® 1$ 1.26
10$ 1.13
25$ 1.07
100$ 0.88
250$ 0.82
500$ 0.73
1000$ 0.57
N/A 9545$ 1.77
Tape & Reel (TR) 3000$ 0.47
NewarkEach (Supplied on Cut Tape) 1$ 1.22
10$ 0.98
25$ 0.94
50$ 0.90
100$ 0.85
250$ 0.84
500$ 0.83
1000$ 0.81

Description

General part information

STEF12 Series

The STEF12E is an integrated electronic fuse optimized for monitoring output current and input voltage. Connected in series to a 12 V rail, it is capable of protecting the electronic circuitry on its output from overcurrent and overvoltage. The device has a controlled delay and turn-on time. When an overload condition occurs, the STEF12E limits the output current to a predefined safe value. If the anomalous overload condition persists it goes into an open state, disconnecting the load from the power supply. If a continuous short-circuit is present on the board, when power is re-applied the E-fuse initially limits the output current to a safe value and then again goes into an open state. The device is equipped with a thermal protection circuit. The intervention of the thermal protection is signalled to the board monitoring circuits through a signal on the Fault pin. Unlike the mechanical fuses, which must be physically replaced after a single event, the Efuse does not degrade in its performance after short-circuit/thermal protection interventions and it is reset either by recycling the supply voltage or using the Enable pin. The companion chip for the 5 V power rails is also available with part number STEF05.