Zenode.ai Logo
Beta
MSOP / 8
Sensors, Transducers

MCP9803-M/MS

Active
Microchip Technology

MSOP HIGH-ACCURACY, 12-BIT THERMAL SENSOR WITH SERIAL INTERFACE AND BUS TIMEOUT ROHS COMPLIANT: YES

Deep-Dive with AI

Search across all available documentation for this part.

MSOP / 8
Sensors, Transducers

MCP9803-M/MS

Active
Microchip Technology

MSOP HIGH-ACCURACY, 12-BIT THERMAL SENSOR WITH SERIAL INTERFACE AND BUS TIMEOUT ROHS COMPLIANT: YES

Technical Specifications

Parameters and characteristics for this part

SpecificationMCP9803-M/MS
Accuracy - Highest (Lowest)1 °C, 3 °C
FeaturesProgrammable Resolution, One-Shot, Programmable Limit, Shutdown Mode, Output Switch
Mounting TypeSurface Mount
Operating Temperature [Max]125 °C
Operating Temperature [Min]-55 °C
Output TypeI2C/SMBus
Package / Case8-MSOP, 8-TSSOP
Package / Case3 mm
Package / Case [custom]0.118 in
Resolution11 b
Sensing Temperature - Local [Max]125 °C
Sensing Temperature - Local [Min]-55 ¯C
Sensor TypeDigital, Local
Supplier Device Package8-MSOP
Test Condition [Max]85 °C
Test Condition [Max]125 °C
Test Condition [Min]-10 °C
Test Condition [Min]-55 °C
Voltage - Supply [Max]5.5 V
Voltage - Supply [Min]2.7 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyTube 1$ 1.48
25$ 1.24
100$ 1.13
Microchip DirectTUBE 1$ 1.48
25$ 1.24
100$ 1.13
1000$ 1.08
5000$ 1.07
NewarkEach 1$ 1.54
10$ 1.41
25$ 1.29
50$ 1.24
100$ 1.18

Description

General part information

MCP9803 Series

The MCP9803 is a digital temperature sensor capable of reading temperatures from -55°C to +125°C. Temperature data is measured from an integrated temperature sensor and converted to digital word with a user selectable 9 to 12-bit Sigma Delta Analog to Digital Converter.

The MCP9803 notifies the host controller when the ambient temperature exceeds a user programmed set point. The ALERT output is programmable as either a simple comparator for thermostat operation or as a temperature event interrupt. Communication with the sensor is accomplished via a two-wire bus that is compatible with industry standard protocols. This permits reading the current temperature, programming the set point and hysteresis, and configuring the device. Address selection inputs allow up to eight MCP9803 sensors to share the same 2-wire bus for multizone monitoring. The MCP9803 also contains SMBus Timeout logic for improved system reliability.

Small physical size, low installed cost, and ease of use