Zenode.ai Logo
Beta
No image
Integrated Circuits (ICs)

ADR1399KEZ

Active
Analog Devices

OVEN-COMPENSATED, BURIED ZENER, 7.05 V VOLTAGE REFERENCE

Deep-Dive with AI

Search across all available documentation for this part.

Integrated Circuits (ICs)

ADR1399KEZ

Active
Analog Devices

OVEN-COMPENSATED, BURIED ZENER, 7.05 V VOLTAGE REFERENCE

Technical Specifications

Parameters and characteristics for this part

SpecificationADR1399KEZ
Current - Cathode [custom]3 mA
Current - Output20 mA
Mounting TypeSurface Mount
Noise - 0.1Hz to 10Hz1.44 µVp-p
Noise - 10Hz to 10kHz1.84 µVrms
Operating Temperature [Max]70 °C
Operating Temperature [Min]0 °C
Output Type1.81 mOhm
Package / Case8-CLCC
Reference TypeShunt, Buried Zener
Supplier Device Package8-LCC (5x5)
Temperature Coefficient1 ppm/°C
Tolerance0.05 %
Voltage - Output (Min/Fixed)7.05 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyTray 1$ 25.80
10$ 19.07
25$ 17.34
80$ 15.68
230$ 14.56
440$ 14.41

Description

General part information

ADR1399 Series

The ADR1399 precision shunt reference features excellent temperature stability over a wide range of voltage, temperature, and quiescent current conditions. A temperature stabilizing loop is incorporated with the active Zener on a monolithic substrate, which nearly eliminates changes in voltage with temperature. The subsurface Zener circuit is fully specified at a quiescent current IREFof 3 mA and offers minimal noise (1.44 μV p-p, 0.1 Hz to 10 Hz) and excellent long-term stability (7 ppm/√kHr). The ADR1399 offers a lower output dynamic impedance (0.08 Ω) than the LM399, reducing the effects of shunt resistor (RSHUNT) and the supply voltage variation on the reference output.Ideal applications for the ADR1399 include ultrastable digital voltmeters, precision calibration equipment, and ultrarepeatable analog-to-digital converters (ADCs). The simplicity of the basic pin configurations is shown in Figure 1. The 8-terminal LCC version offers force and sense pins for lower dynamic impedance and for Kelvin sensing.Table 1. Related ProductsModelOutput Voltage (V)Initial Accuracy Range (mV)ADR13997.05–300 to +250LTZ10007.2–200 to +300LM3996.95–200 to +350LT12365 and 10–2.5 to +2.5APPLICATIONSPrecision voltage reference for multimetersCalibration equipment voltage standardsLaboratory measurement equipmentIndustrial monitor and control instrumentationUltrastable data convertors