ISO808TR-1
ActiveGALVANIC ISOLATED OCTAL HIGH-SIDE POWER SOLID STATE RELAY FOR HIGH INDUCTIVE LOADS
Deep-Dive with AI
Search across all available documentation for this part.

ISO808TR-1
ActiveGALVANIC ISOLATED OCTAL HIGH-SIDE POWER SOLID STATE RELAY FOR HIGH INDUCTIVE LOADS
Deep-Dive with AI
Technical Specifications
Parameters and characteristics for this part
| Specification | ISO808TR-1 |
|---|---|
| Current - Output (Max) [Max] | 1 A |
| Fault Protection | Over Voltage, Current Limiting (Fixed), Short Circuit, UVLO, Over Temperature, Reverse Battery |
| Features | Status Flag, Auto Restart, Watchdog Timer |
| Input Type | CMOS |
| Interface | Parallel |
| Mounting Type | Surface Mount |
| Number of Outputs | 8 |
| Operating Temperature [Max] | 125 °C |
| Operating Temperature [Min] | -40 C |
| Output Configuration | High Side |
| Output Type | N-Channel |
| Package / Case | 36-PowerBSSOP |
| Package / Case [x] | 0.433 " |
| Package / Case [y] | 11 mm |
| Ratio - Input:Output | 1:1 |
| Rds On (Typ) | 125 mOhm |
| Supplier Device Package | PowerSO-36, Bottom Pad |
| Switch Type | Relay, Solenoid Driver |
| Voltage - Load [Max] | 36 V |
| Voltage - Load [Min] | 9.2 V |
| Voltage - Supply (Vcc/Vdd) [Max] | 5.5 V |
| Voltage - Supply (Vcc/Vdd) [Min] | 2.75 V |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
Description
General part information
ISO808-1 Series
The ISO808, ISO808-1 (PowerSO-36) and ISO808Q, ISO808Q-1 (TFQFPN32) are galvanic isolated 8-channel drivers featuring a low supply current. Each driver contains 2 independent galvanic isolated voltage domains (VCC and VDD for the Process and Control Logic stages, respectively). The ICs are intended for driving any kind of load with one side connected to ground.
Active channel current limitation (OVL) combined with thermal shutdown (OVT), independent for each channel, protects the device against overload.
Built-in thermal shutdown protects each channel from overtemperature and overload: each overheated channel automatically turns OFF after its junction temperature triggers the protection threshold (TJSD). The channel turns back ON if its junction temperature decreases lower than restart threshold (TJR).
Documents
Technical documentation and resources