Zenode.ai Logo
Beta
STEF033PUR
Integrated Circuits (ICs)

STEF033PUR

Active
STMicroelectronics

CIRCUIT PROTECTION MISC ELECTRONIC FUSE FOR 3.3V LINE

Deep-Dive with AI

Search across all available documentation for this part.

STEF033PUR
Integrated Circuits (ICs)

STEF033PUR

Active
STMicroelectronics

CIRCUIT PROTECTION MISC ELECTRONIC FUSE FOR 3.3V LINE

Deep-Dive with AI

Technical Specifications

Parameters and characteristics for this part

SpecificationSTEF033PUR
FunctionElectronic Fuse
Mounting TypeSurface Mount
Operating Temperature [Max]125 °C
Operating Temperature [Min]-40 C
Package / Case10-VFDFN Exposed Pad
Supplier Device Package10-DFN (3x3)

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyN/A 60$ 2.10
NewarkEach (Supplied on Cut Tape) 1$ 1.32
10$ 0.95
25$ 0.91
50$ 0.87
100$ 0.83
250$ 0.81
500$ 0.80
1000$ 0.78

Description

General part information

STEF033 Series

The STEF033 is an integrated electronic fuse optimized for monitoring output current and the input voltage. Connected in series to the 3.3 V rail, it is able to protect the electronic circuitry on its output from overcurrent and overvoltage. The STEF033 has controlled delay and turn-on time. When an overload condition occurs, the device limits the output current to a predefined safe value. If the anomalous overload condition persists, it goes into an open state, disconnecting the load from the power supply. If a continuous short-circuit is present on the board, when the power is re-applied the E-fuse initially limits the output current to a safe value and then goes again into the open state. The voltage clamping circuit prevents the output voltage from exceeding a fixed value, if the input voltage goes beyond this threshold. The device is equipped with a thermal protection circuit. Intervention of thermal protection is signaled to the board-monitoring circuits through an appropriate signal on the Fault pin. Unlike mechanical fuses, which must be physically replaced after a single event, the E-fuse does not degrade in its performances following short-circuit/thermal protection intervention and is reset either by re-cycling the supply voltage or using the appropriate Enable pin. The STEF033 is also available in an auto-retry version; in case of thermal fault it automatically attempts to re-apply power to the load when the die temperature returns to a safe value.