LPS28DFWTR
ActiveDUAL FULL-SCALE, 1260 HPA AND 4060 HPA, ABSOLUTE DIGITAL OUTPUT BAROMETER WITH WATER-RESISTANT PACKAGE
Deep-Dive with AI
Search across all available documentation for this part.

LPS28DFWTR
ActiveDUAL FULL-SCALE, 1260 HPA AND 4060 HPA, ABSOLUTE DIGITAL OUTPUT BAROMETER WITH WATER-RESISTANT PACKAGE
Deep-Dive with AI
Technical Specifications
Parameters and characteristics for this part
| Specification | LPS28DFWTR |
|---|---|
| Accuracy | 0.05 kPa |
| Accuracy | 0.01 PSI |
| Applications | Board Mount |
| Features | Temperature Compensated |
| Maximum Pressure | 1000 kPa |
| Maximum Pressure [Max] | 145.04 PSI |
| Mounting Type | Surface Mount |
| Operating Pressure [Max] | 406 kPa |
| Operating Pressure [Max] | 58.89 PSI |
| Operating Pressure [Min] | 26 kPa |
| Operating Pressure [Min] | 3.77 PSI |
| Operating Temperature [Max] | 85 °C |
| Operating Temperature [Min] | -40 C |
| Output | 24 b |
| Output Type | I3C, I2C |
| Package / Case | 6-CLGA |
| Port Style | No Port |
| Supplier Device Package | CCLGA-7L |
| Voltage - Supply [Max] | 3.6 V |
| Voltage - Supply [Min] | 1.7 V |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
Description
General part information
LPS28DFW Series
The LPS28DFW is an ultra-compact piezoresistive absolute pressure sensor which functions as a digital output barometer. The device comprises a sensing element and an IC interface which communicates over the I²C or MIPI I3CSMinterface from the sensing element to the application. The LPS28DFW provides lower power consumption, achieving lower pressure noise than its predecessor.
The LPS28DFW is available in a ceramic LGA package with a metal lid. It is guaranteed to operate over a temperature range extending from -40 °C to +85 °C. The package is holed to allow external pressure to reach the sensing element. Gel inside the IC protects the electrical components from water and the metal cap is, optionally, connected to ground or left floating electrically in the application PCB layout. The connection of the metal cap is determined according to the customer’s target application.
This device has been designed to meet the requirements and mission profile for personal electronics and consumer applications.