Technical Specifications
Parameters and characteristics for this part
| Specification | VMS-100-28 |
|---|---|
| Applications | Medical |
| Approval Agency | UL, IEC, FCC, TUV, EN, CB Scheme |
| Current - Output 1 | 3.6 A |
| Efficiency | 91 % |
| Features | Adjustable Output, PFC, Universal Input, Remote Sense |
| Minimum Load Required | False |
| Mounting Type | Chassis Mount |
| Number of Outputs | 1 |
| Operating Temperature [Max] | 70 °C |
| Operating Temperature [Min] | -25 °C |
| Power (Watts) | 100 W |
| Size / Dimension [x] | 127 mm |
| Size / Dimension [x] | 5 " |
| Size / Dimension [y] | 76.2 mm |
| Size / Dimension [y] | 3 " |
| Size / Dimension [z] | 26.7 mm |
| Size / Dimension [z] | 1.05 in |
| Standard Number | 55024, 60601-1, 61204-3, 61000-3-3, 61000-6-1, 61000-6-4, 61000-3-2, 60950-1, 55032 Class A, 61000-6-3 |
| Type | Open Frame |
| Voltage - Input [Max] | 264 VAC |
| Voltage - Input [Min] | 90 VAC |
| Voltage - Isolation | 5656 V |
| Voltage - Output 1 | 28 V |
| Part | Mounting Type | Voltage - Isolation | Efficiency | Current - Output 1 | Voltage - Input [Max] | Voltage - Input [Min] | Size / Dimension [y] | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [x] | Size / Dimension [x] | Size / Dimension [z] | Features | Power (Watts) | Number of Outputs | Applications | Minimum Load Required | Voltage - Output 1 [custom] | Operating Temperature [Max] | Operating Temperature [Min] | Type | Standard Number | Approval Agency | Voltage - Output 1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CUI Inc. | Chassis Mount | 5656 V | 91 % | 2.8 A | 264 VAC | 90 VAC | 76.2 mm | 26.7 mm | 3 " | 127 mm | 5 " | 1.05 in | Adjustable Output PFC Remote Sense Universal Input | 100 W | 1 | Medical | 36 V | 70 °C | -25 °C | Open Frame | 55024 55032 Class A 60601-1 60950-1 61000-3-2 61000-3-3 61000-6-1 61000-6-3 61000-6-4 61204-3 | CB Scheme EN FCC IEC TUV UL | ||
CUI Inc. | Chassis Mount | 5656 V | 89 % | 8.4 A | 264 VAC | 90 VAC | 76.2 mm | 26.7 mm | 3 " | 127 mm | 5 " | 1.05 in | Adjustable Output PFC Remote Sense Universal Input | 100 W | 1 | Medical | 70 °C | -25 °C | Open Frame | 55024 55032 Class A 60601-1 60950-1 61000-3-2 61000-3-3 61000-6-1 61000-6-3 61000-6-4 61204-3 | CB Scheme EN FCC IEC TUV UL | 12 V | ||
CUI Inc. | Chassis Mount | 5656 V | 88 % | 11.2 A | 264 VAC | 90 VAC | 76.2 mm | 26.7 mm | 3 " | 127 mm | 5 " | 1.05 in | Adjustable Output PFC Remote Sense Universal Input | 100 W | 1 | Medical | 70 °C | -25 °C | Open Frame | 55024 55032 Class A 60601-1 60950-1 61000-3-2 61000-3-3 61000-6-1 61000-6-3 61000-6-4 61204-3 | CB Scheme EN FCC IEC TUV UL | 9 V | ||
CUI Inc. | Chassis Mount | 5656 V | 89 % | 6.7 A | 264 VAC | 90 VAC | 76.2 mm | 26.7 mm | 3 " | 127 mm | 5 " | 1.05 in | Adjustable Output PFC Remote Sense Universal Input | 100 W | 1 | Medical | 70 °C | -25 °C | Open Frame | 55024 55032 Class A 60601-1 60950-1 61000-3-2 61000-3-3 61000-6-1 61000-6-3 61000-6-4 61204-3 | CB Scheme EN FCC IEC TUV UL | 15 V | ||
CUI Inc. | Chassis Mount | 5656 V | 85 % | 20 A | 264 VAC | 90 VAC | 76.2 mm | 26.7 mm | 3 " | 127 mm | 5 " | 1.05 in | Adjustable Output PFC Remote Sense Universal Input | 100 W | 1 | Medical | 70 °C | -25 °C | Open Frame | 55024 55032 Class A 60601-1 60950-1 61000-3-2 61000-3-3 61000-6-1 61000-6-3 61000-6-4 61204-3 | CB Scheme EN FCC IEC TUV UL | 5 V | ||
CUI Inc. | Chassis Mount | 5656 V | 91 % | 2.1 A | 264 VAC | 90 VAC | 76.2 mm | 26.7 mm | 3 " | 127 mm | 5 " | 1.05 in | Adjustable Output PFC Remote Sense Universal Input | 100 W | 1 | Medical | 70 °C | -25 °C | Open Frame | 55024 55032 Class A 60601-1 60950-1 61000-3-2 61000-3-3 61000-6-1 61000-6-3 61000-6-4 61204-3 | CB Scheme EN FCC IEC TUV UL | 48 V | ||
CUI Inc. | Chassis Mount | 5656 V | 91 % | 3.6 A | 264 VAC | 90 VAC | 76.2 mm | 26.7 mm | 3 " | 127 mm | 5 " | 1.05 in | Adjustable Output PFC Remote Sense Universal Input | 100 W | 1 | Medical | 70 °C | -25 °C | Open Frame | 55024 55032 Class A 60601-1 60950-1 61000-3-2 61000-3-3 61000-6-1 61000-6-3 61000-6-4 61204-3 | CB Scheme EN FCC IEC TUV UL | 28 V | ||
CUI Inc. | Chassis Mount | 5656 V | 91 % | 4.2 A | 264 VAC | 90 VAC | 76.2 mm | 26.7 mm | 3 " | 127 mm | 5 " | 1.05 in | Adjustable Output PFC Remote Sense Universal Input | 100 W | 1 | Medical | 70 °C | -25 °C | Open Frame | 55024 55032 Class A 60601-1 60950-1 61000-3-2 61000-3-3 61000-6-1 61000-6-3 61000-6-4 61204-3 | EN FCC TUV UL | 24 V | ||
CUI Inc. | Chassis Mount | 5656 V | 90 % | 5.6 A | 264 VAC | 90 VAC | 76.2 mm | 26.7 mm | 3 " | 127 mm | 5 " | 1.05 in | Adjustable Output PFC Remote Sense Universal Input | 100 W | 1 | Medical | 70 °C | -25 °C | Open Frame | 55024 55032 Class A 60601-1 60950-1 61000-3-2 61000-3-3 61000-6-1 61000-6-3 61000-6-4 61204-3 | EN FCC TUV UL | 18 V |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
| Distributor | Package | Quantity | $ | |
|---|---|---|---|---|
| Digikey | N/A | 0 | $ 74.39 | |
Description
General part information
VMS-100 Series
Open Frame AC DC Converters 1 Output 28V 90 ~ 264 VAC Input
Documents
Technical documentation and resources
No documents available