AFE4960YBGR
Integrated Circuits (ICs)

AFE4960PYBGR

Active
Texas Instruments

TWO-CHANNEL ECG AND PPG ANALOG FRONT END WITH INTEGRATED RESPIRATION AND PACE DETECTION

Deep-Dive with AI

Search across all available documentation for this part.

AFE4960YBGR
Integrated Circuits (ICs)

AFE4960PYBGR

Active
Texas Instruments

TWO-CHANNEL ECG AND PPG ANALOG FRONT END WITH INTEGRATED RESPIRATION AND PACE DETECTION

Technical Specifications

Parameters and characteristics for this part

SpecificationAFE4960PYBGR
Mounting TypeSurface Mount
Number of Bits22
Number of Channels [custom]2
Supplier Device Package36-DSBGA (2.63x2.46)
Voltage - Supply, Analog [Max]1.9 V
Voltage - Supply, Analog [Min]1.7 V
Voltage - Supply, Digital [Max]1.9 V
Voltage - Supply, Digital [Min]1.7 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyTape & Reel (TR) 3000$ 8.41
Texas InstrumentsLARGE T&R 1$ 10.54
100$ 9.21
250$ 7.10
1000$ 6.35

Description

General part information

AFE4960P Series

The AFE4960P supports synchronized signal acquisition of ECG, PPG and bio-impedance signals. A PPG signal chain comprises of a current driver for LEDs and a receiver that senses the signal from PDs. The AFE can be configured as either a 2-channel ECG receiver or as a 1-channel ECG receiver and a Respiration impedance channel. The AFE signal chains can interface in a flexible manner to up to 4 electrodes. The AFE has AC and DC Lead biasing and lead on/off detection. Pacemaker pulse detection is supported on one channel. All the signal chain outputs are converted by a single ADC in well-defined time slots and stored as 24-bit words in a 128-sample FIFO which can be read out using a SPI or an I2C interface. The AFE4960P can be used to realize a 3-lead ECG system along with SpO2.

The AFE4960P supports synchronized signal acquisition of ECG, PPG and bio-impedance signals. A PPG signal chain comprises of a current driver for LEDs and a receiver that senses the signal from PDs. The AFE can be configured as either a 2-channel ECG receiver or as a 1-channel ECG receiver and a Respiration impedance channel. The AFE signal chains can interface in a flexible manner to up to 4 electrodes. The AFE has AC and DC Lead biasing and lead on/off detection. Pacemaker pulse detection is supported on one channel. All the signal chain outputs are converted by a single ADC in well-defined time slots and stored as 24-bit words in a 128-sample FIFO which can be read out using a SPI or an I2C interface. The AFE4960P can be used to realize a 3-lead ECG system along with SpO2.