AFE4960PYBGR
ActiveTWO-CHANNEL ECG AND PPG ANALOG FRONT END WITH INTEGRATED RESPIRATION AND PACE DETECTION
Deep-Dive with AI
Search across all available documentation for this part.

AFE4960PYBGR
ActiveTWO-CHANNEL ECG AND PPG ANALOG FRONT END WITH INTEGRATED RESPIRATION AND PACE DETECTION
Deep-Dive with AI
Technical Specifications
Parameters and characteristics for this part
| Specification | AFE4960PYBGR |
|---|---|
| Mounting Type | Surface Mount |
| Number of Bits | 22 |
| Number of Channels [custom] | 2 |
| Supplier Device Package | 36-DSBGA (2.63x2.46) |
| Voltage - Supply, Analog [Max] | 1.9 V |
| Voltage - Supply, Analog [Min] | 1.7 V |
| Voltage - Supply, Digital [Max] | 1.9 V |
| Voltage - Supply, Digital [Min] | 1.7 V |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
| Distributor | Package | Quantity | $ | |
|---|---|---|---|---|
| Digikey | Tape & Reel (TR) | 3000 | $ 8.41 | |
| Texas Instruments | LARGE T&R | 1 | $ 10.54 | |
| 100 | $ 9.21 | |||
| 250 | $ 7.10 | |||
| 1000 | $ 6.35 | |||
Description
General part information
AFE4960P Series
The AFE4960P supports synchronized signal acquisition of ECG, PPG and bio-impedance signals. A PPG signal chain comprises of a current driver for LEDs and a receiver that senses the signal from PDs. The AFE can be configured as either a 2-channel ECG receiver or as a 1-channel ECG receiver and a Respiration impedance channel. The AFE signal chains can interface in a flexible manner to up to 4 electrodes. The AFE has AC and DC Lead biasing and lead on/off detection. Pacemaker pulse detection is supported on one channel. All the signal chain outputs are converted by a single ADC in well-defined time slots and stored as 24-bit words in a 128-sample FIFO which can be read out using a SPI or an I2C interface. The AFE4960P can be used to realize a 3-lead ECG system along with SpO2.
The AFE4960P supports synchronized signal acquisition of ECG, PPG and bio-impedance signals. A PPG signal chain comprises of a current driver for LEDs and a receiver that senses the signal from PDs. The AFE can be configured as either a 2-channel ECG receiver or as a 1-channel ECG receiver and a Respiration impedance channel. The AFE signal chains can interface in a flexible manner to up to 4 electrodes. The AFE has AC and DC Lead biasing and lead on/off detection. Pacemaker pulse detection is supported on one channel. All the signal chain outputs are converted by a single ADC in well-defined time slots and stored as 24-bit words in a 128-sample FIFO which can be read out using a SPI or an I2C interface. The AFE4960P can be used to realize a 3-lead ECG system along with SpO2.