54010
Switches

54010

Obsolete
LITTELFUSE

SW RKR SPDT/ BULK ROHS COMPLIANT: YES

Deep-Dive with AI

Search across all available documentation for this part.

54010
Switches

54010

Obsolete
LITTELFUSE

SW RKR SPDT/ BULK ROHS COMPLIANT: YES

Deep-Dive with AI

Technical Specifications

Parameters and characteristics for this part

Specification54010
Actuator MarkingNo Marking
Actuator TypeConcave (Curved)
CircuitSPDT
Color - Actuator/CapBlack
Current Rating10 A
Mounting TypePanel Mount, Snap-In
Panel Cutout Length28.57 mm
Panel Cutout ShapeRectangular
Panel Cutout Width13.97 mm
Quick Connect Size (0.250")0.25 in
Switch FunctionOn-On
Termination StyleQuick Connect
Voltage Rating - DC12 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$Updated
DigikeyBulk 1$ 8.49<1d
10$ 7.33
25$ 6.91
NewarkEach 1$ 10.761m+
50$ 6.38
100$ 5.62
250$ 5.36
500$ 4.98
TMEN/A 1$ 5.07<1d
3$ 4.59
5$ 4.06
10$ 3.58

CAD

3D models and CAD resources for this part

Description

General part information

- Series

The ARP Series is used in systems where equal run time for two motors is desirable. The selector switch allows selection of alternation of either load for continuous operation. LED’s indicate the status of the output relay. This versatile series may be front panel mounted (BZ1 accessory required) or 35 mm DIN rail mounted with an accessory socket. Operation Alternating: When the rotary switch is in the "alternate" position, alternating operation of Load A and Load B occurs upon the opening of the control switch S1. To terminate alternating operation and cause only the selected load to operate, rotate the switch to position "A" to lock Load A or position "B" to lock Load B. The LEDs indicate the status of the internal relay and which load is selected to operate. Note: Input voltage must be applied at all times for proper alternation. The use of a solid-state control switch for S1 may not initiate alternation correctly. S1 voltage must be from the same supply as the unit’s input voltage (see connection diagrams on datasheet). Loss of input voltage resets the unit; Load A becomes the lead load for the next operation. Duplexing (Cross Wired): Duplexing models operate the same as alternating relays and when both the Control (S1) and Lag Load (S2) Switches are closed, Load A and Load B energize simultaneously. The DPDT 8-pin, cross-wired option, allows extra system load capacity through simultaneous operation of both motors when needed. Relay contacts are not isolated.

Documents

Technical documentation and resources