Zenode.ai Logo
Beta
8-VSSOP
Integrated Circuits (ICs)

LM5068MM-4/NOPB

Active
Texas Instruments

HOT SWAP CONTROLLER 1-CH -10V N-CHANNEL NEGATIVE VOLTAGE 8-PIN VSSOP T/R

Deep-Dive with AI

Search across all available documentation for this part.

8-VSSOP
Integrated Circuits (ICs)

LM5068MM-4/NOPB

Active
Texas Instruments

HOT SWAP CONTROLLER 1-CH -10V N-CHANNEL NEGATIVE VOLTAGE 8-PIN VSSOP T/R

Deep-Dive with AI

Technical Specifications

Parameters and characteristics for this part

SpecificationLM5068MM-4/NOPB
Applications-48 V
Current - Supply820 µA
FeaturesAuto Retry, Turn On Voltage
Internal Switch(s)False
Mounting TypeSurface Mount
Number of Channels1
Operating Temperature [Max]105 ░C
Operating Temperature [Min]-40 °C
Package / Case8-MSOP, 8-TSSOP
Package / Case3 mm
Package / Case [custom]0.118 in
Programmable FeaturesCurrent Limit, Circuit Breaker, UVLO, OVP, Fault Timeout
TypeHot Swap Controller
Voltage - Supply [Max]-10 V
Voltage - Supply [Min]-90 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyCut Tape (CT) 1$ 3.41
10$ 3.06
25$ 2.90
100$ 2.51
250$ 2.38
500$ 2.14
Digi-Reel® 1$ 3.41
10$ 3.06
25$ 2.90
100$ 2.51
250$ 2.38
500$ 2.14
Tape & Reel (TR) 1000$ 1.80
2000$ 1.71
5000$ 1.65
Texas InstrumentsLARGE T&R 1$ 2.58
100$ 2.26
250$ 1.58
1000$ 1.27

Description

General part information

LM5068 Series

The LM5068 hot-swap controller provides intelligent control of power supply connections during the insertion and removal of circuit cards powered by live system backplanes.

The LM5068 provides both in-rush current control and short-circuit protection functions, and limits power supply transients in the backplane caused by the insertion of additional circuit cards. The LM5068 controls the external N-Channel MOSFET to provide programmable load current limiting and circuit breaker functions using a single external current sense resistor. The LM5068 issues a power good (PWRGD) signal at the conclusion of a successful power-on sequence. Input over-voltage or under -voltage fault conditions will cancel the PWRGD indication.

The LM5068-1 and -2 indicate power-good as an open-drain active HIGH PWRGD state. The LM5068-3 and -4 indicate power-good as an open-drain active LOW PWRGD state. The LM5068-1 and -3 latch off after a fault condition is detected while the LM5068-2 and -4 continuously re-try at intervals set by a programmable timer.