| Specification | QPD-50-12 |
|---|---|
| Applications | ITE (Commercial) |
| Approval Agency | cURus, CB, CE |
| Current - Output 1 | 4.2 A |
| Efficiency | 85 % |
| Features | Adjustable Output, Universal Input, DC Input Capable |
| Mounting Type | Chassis Mount |
| Number of Outputs | 1 |
| Operating Temperature [Max] | 70 °C |
| Operating Temperature [Min] | -25 °C |
| Power (Watts) | 50 W |
| Size / Dimension [x] | 3.9 " |
| Size / Dimension [x] | 99 mm |
| Size / Dimension [y] | 3.23 in |
| Size / Dimension [y] | 82 mm |
| Size / Dimension [z] | 35 mm |
| Size / Dimension [z] | 1.38 in |
| Type | Enclosed |
| Voltage - Input [Max] | 264 VAC |
| Voltage - Input [Min] | 90 VAC |
| Voltage - Isolation | 3000 V |
| Voltage - Output 1 | 12 V |
| Part | Mounting Type | Efficiency | Features | Operating Temperature [Max] | Operating Temperature [Min] | Voltage - Output 1 | Power (Watts) | Size / Dimension [x] | Size / Dimension [y] | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [z] | Size / Dimension [x] | Approval Agency | Voltage - Isolation | Applications | Type | Number of Outputs | Voltage - Input [Max] | Voltage - Input [Min] | Current - Output 1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Qualtek | Chassis Mount | 86 % | Adjustable Output DC Input Capable Universal Input | 70 °C | -25 °C | 15 V | 50 W | 3.9 " | 3.23 in | 35 mm | 82 mm | 1.38 in | 99 mm | CB CE cURus | 3000 V | ITE (Commercial) | Enclosed | 1 | 264 VAC | 90 VAC | 3.4 A |
Qualtek | Chassis Mount | 89 % | Adjustable Output DC Input Capable Universal Input | 70 °C | -25 °C | 48 V | 50 W | 3.9 " | 3.23 in | 35 mm | 82 mm | 1.38 in | 99 mm | CB CE cURus | 3000 V | ITE (Commercial) | Enclosed | 1 | 264 VAC | 90 VAC | 1.12 A |
Qualtek | Chassis Mount | 80 % | Adjustable Output DC Input Capable Universal Input | 70 °C | -25 °C | 5 V | 50 W | 3.9 " | 3.23 in | 35 mm | 82 mm | 1.38 in | 99 mm | CB CE cURus | 3000 V | ITE (Commercial) | Enclosed | 1 | 264 VAC | 90 VAC | 8 A |
Qualtek | Chassis Mount | 85 % | Adjustable Output DC Input Capable Universal Input | 70 °C | -25 °C | 12 V | 50 W | 3.9 " | 3.23 in | 35 mm | 82 mm | 1.38 in | 99 mm | CB CE cURus | 3000 V | ITE (Commercial) | Enclosed | 1 | 264 VAC | 90 VAC | 4.2 A |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
| Distributor | Package | Quantity | $ | |
|---|---|---|---|---|
| Digikey | Bulk | 100 | $ 30.44 | |
| N/A | 0 | $ 30.85 | ||
Description
General part information
QPD-50 Series
Enclosed AC DC Converters 1 Output 12V 90 ~ 264 VAC Input