MAX86171ENI+T
ActiveLOW-NOISE AFE FOR PULSE OXIMETER AND HEART RATE MONITOR
Deep-Dive with AI
Search across all available documentation for this part.

MAX86171ENI+T
ActiveLOW-NOISE AFE FOR PULSE OXIMETER AND HEART RATE MONITOR
Deep-Dive with AI
Technical Specifications
Parameters and characteristics for this part
| Specification | MAX86171ENI+T |
|---|---|
| Operating Temperature [Max] | 85 °C |
| Operating Temperature [Min] | -40 C |
| Output Type | SPI |
| Sensor Type | Oximeter/Heart Rate |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
| Distributor | Package | Quantity | $ | |
|---|---|---|---|---|
| Digikey | Cut Tape (CT) | 1 | $ 12.91 | |
| 10 | $ 9.12 | |||
| 25 | $ 8.14 | |||
| 100 | $ 7.05 | |||
| 250 | $ 6.53 | |||
| 500 | $ 6.20 | |||
| 1000 | $ 5.99 | |||
| Digi-Reel® | 1 | $ 12.91 | ||
| 10 | $ 9.12 | |||
| 25 | $ 8.14 | |||
| 100 | $ 7.05 | |||
| 250 | $ 6.53 | |||
| 500 | $ 6.20 | |||
| 1000 | $ 5.99 | |||
| N/A | 4893 | $ 10.78 | ||
| Tape & Reel (TR) | 2500 | $ 5.99 | ||
Description
General part information
MAX86171 Series
The MAX86171 is an ultra-low-power optical data acquisition system with both transmit and receive channels. On the transmitter side, the MAX86171 has nine LED driver output pins, programmable from three high-current, 8-bit LED drivers. On the receiver side, MAX86171 has two low-noise charge integrating front-ends that each include independent 19.5 bit ADCs and best-in-class ambient light cancellation (ALC) circuits, producing the highest performing integrated optical data acquisition system on the market today.Due to its low power consumption, compact size, ease and flexibility of use, the MAX86171 is ideal for a wide variety of optical sensing applications such as pulse oximetry and heart rate detection.The MAX86171 operates on a 1.8V main supply voltage and a 3.1V to 5.5V LED driver supply voltage. The device supports both I2C and SPI compatible interfaces in a fully autonomous way. The device has a large 256-word built-in FIFO. The MAX86171 is available in a compact 28-bump WLP package.ApplicationsWearable Devices for Fitness, Wellness, and Medical ApplicationsClinical AccuracySuitable for Wrist, Finger, Ear, and Other LocationsOptimized Performance to Detect:Optical Heart RateHeart Rate VariabilityOxygen Saturation (SpO2)Body HydrationMuscle and Tissue Oxygen Saturation (SmO2and StO2)Maximum Oxygen Consumption (VO2max)
Documents
Technical documentation and resources