KLLU2000X
ActiveFUSE CARTRIDGE 2KA 600VAC/300VDC
Deep-Dive with AI
Search across all available documentation for this part.

KLLU2000X
ActiveFUSE CARTRIDGE 2KA 600VAC/300VDC
Deep-Dive with AI
Technical Specifications
Parameters and characteristics for this part
| Specification | KLLU2000X |
|---|---|
| Applications | Electrical, Industrial |
| Approval Agency | UL, CSA, CE |
| Breaking Capacity @ Rated Voltage | 20 kA, 200 kA |
| Class | L |
| Current Rating (Amps) | 2 kA |
| Fuse Type | Cartridge |
| Mounting Type | Bolt Mount |
| Package / Case | Cylindrical, Blade Terminal (Bolt) |
| Response Time | Slow Blow |
| Size / Dimension [diameter] | 3.5 " |
| Size / Dimension [diameter] | 88.9 mm |
| Size / Dimension [x] | 3.752 in |
| Size / Dimension [x] | 95.3 mm |
| Voltage Rating - AC | 600 VAC |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
Description
General part information
KLLU2000 Series
KLLU series UL Listed, time-delay, Class L are quality fuses in every sense of the word. They were developed to provide a somewhat lower priced alternate to the POWR-PRO™ KLPC series fuses. KLLU series fuses meet or exceed all UL requirements for Class L fuses. For superior protection and performance, specification-grade POWR-PRO™ KLPC series fuses are the recommended fuses.Safety: 200,000 A.I.R. — Provides reliable interruption of all overcurrents up to 200,000 amperes. When used for motor branch circuit protection, KLLU fuses may be sized close to the motor full-load current, providing excellent protection to branch circuit conductors, motor control equipment and motors. Longer Equipment Life: Current limiting — Reduces short circuit damage to systems and equipment. Reduced downtime Ten second minimum time delay at 500 percent of rating eliminates needless downtime caused by heavy starting currents of large motors and other inductive loads. Selective coordination — KLLU fuses coordinate well with other Class L fuses and with all current-limiting Littelfuse fuses rated 600 amps or less. This means less time spent trying to locate short circuits or overloaded equipment, because only the fuse immediately on the line side of the affected circuit opens. Easy to Use: 200,000 A.I.R. rating minimizes need for short circuit calculations…meets present and future system requirements. KLLU fuse time-current characteristics closely match typical time-current curves of circuit breakers. Although fuse/circuit breaker systems can seldom be 100% coordinated , KLLU series fuses permit use of a wider range of breaker setting than fast-acting Class L fuses. Excellent protection for a single breaker or a group of breakers.
Documents