Zenode.ai Logo
Beta
24 VFQFN
Integrated Circuits (ICs)

TPS259802ONRGER

Active
Texas Instruments

2.7-V TO 24-V, 8-A, 3-MΩ SMART EFUSE WITH ADJUSTABLE TRANSIENT FAULT MANAGEMENT

Deep-Dive with AI

Search across all available documentation for this part.

24 VFQFN
Integrated Circuits (ICs)

TPS259802ONRGER

Active
Texas Instruments

2.7-V TO 24-V, 8-A, 3-MΩ SMART EFUSE WITH ADJUSTABLE TRANSIENT FAULT MANAGEMENT

Technical Specifications

Parameters and characteristics for this part

SpecificationTPS259802ONRGER
ApplicationsGeneral Purpose
Current - Output (Max) [Max]8 A
Current - Supply800 çA
FeaturesUVLO, Latched Fault
Internal Switch(s)False
Mounting TypeSurface Mount
Number of Channels1
Operating Temperature [Max]125 °C
Operating Temperature [Min]-40 °C
Package / Case24-VFQFN Exposed Pad
Programmable FeaturesFault Timeout, Latched Fault, OVP, Slew Rate, Circuit Breaker, Current Limit, UVLO
Supplier Device Package24-VQFN (4x4)
TypeHot Swap Controller
Voltage - Supply [Max]24 V
Voltage - Supply [Min]2.7 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyCut Tape (CT) 1$ 2.19
10$ 1.97
25$ 1.86
100$ 1.58
250$ 1.48
500$ 1.30
1000$ 1.08
Digi-Reel® 1$ 2.19
10$ 1.97
25$ 1.86
100$ 1.58
250$ 1.48
500$ 1.30
1000$ 1.08
Tape & Reel (TR) 3000$ 0.90
Texas InstrumentsLARGE T&R 1$ 1.61
100$ 1.33
250$ 0.96
1000$ 0.72

Description

General part information

TPS259802 Series

The TPS25980x family of eFuses is a highly integrated circuit protection and power management solution in a small package. The devices are operational over a wide input voltage range. A single part caters to low-voltage systems needing minimal I*R voltage drop as well as higher voltage, high current systems needing low power dissipation. They are a robust defense against overloads, short-circuits, voltage surges and excessive inrush current.

Overvoltage events are limited by internal cutoff circuits, with multiple device options to choose the overvoltage threshold.

The device provides a circuit-breaker response to overcurrent conditions. The overcurrent limit (circuit-breaker threshold) and fast-trip (short-circuit) threshold can be set with a single external resistor. The devices intelligently manage the overcurrent response by distinguishing between transient events and actual faults, thereby allowing the system to function uninterrupted during line and load transients without compromising on the robustness of the protection against faults. The device can be configured to stay latched off or retry automatically after a fault shutdown. The number of auto-retries as well as the retry delay are configurable with capacitors. This enables remote systems to automatically recover from temporary faults while ensuring that power supplies are not stressed indefinitely due to a persistent fault.