Zenode.ai Logo
Beta
coolx1000-fr-wp
Power Supplies - External/Internal (Off-Board)

CX10S-HBCHCD-P-A-DK00000

Active
EXCELSYS / Advanced Energy

ACDC CNVT 48V 24V 5V 24V 12V 24V

Deep-Dive with AI

Search across all available documentation for this part.

coolx1000-fr-wp
Power Supplies - External/Internal (Off-Board)

CX10S-HBCHCD-P-A-DK00000

Active
EXCELSYS / Advanced Energy

ACDC CNVT 48V 24V 5V 24V 12V 24V

Deep-Dive with AI

Technical Specifications

Parameters and characteristics for this part

SpecificationCX10S-HBCHCD-P-A-DK00000
ApplicationsITE (Commercial), Medical
Approval AgencyUL, EN, CSA, IEC
Current - Output 16 A
Current - Output 23 A
Current - Output 315 A
Current - Output 48.3 A
Current - Output 56 A
Current - Output 63 A
Efficiency93 %
FeaturesAdjustable Output, Universal Input, PMBus™, Standby Output, Remote Sense
Minimum Load RequiredFalse
Mounting TypeChassis Mount
Number of Outputs8
Operating Temperature [Max]85 °C
Operating Temperature [Min]-40 C
Power (Watts)980 W
Size / Dimension [x]10.22 in
Size / Dimension [x]259.5 mm
Size / Dimension [y]164 mm
Size / Dimension [y]6.46 in
Size / Dimension [z]1.6 "
Size / Dimension [z]40.6 mm
Standard Number60950-1, 60601-1, 62368-1
TypeEnclosed
Voltage - Isolation4000 V
Voltage - Output 15 V
Voltage - Output 224 V
Voltage - Output 312 V
Voltage - Output 424 V
Voltage - Output 55 V
Voltage - Output 624 V
...
PartMinimum Load RequiredCurrent - Output 3ApplicationsVoltage - Output 4Number of OutputsStandard NumberApproval AgencyOperating Temperature [Max]Operating Temperature [Min]FeaturesCurrent - Output 2Voltage - Output 5Voltage - IsolationCurrent - Output 1Current - Output 6Voltage - Output 2Mounting TypeSize / Dimension [x]Size / Dimension [x]Size / Dimension [z]Size / Dimension [y]Size / Dimension [y]Size / Dimension [z]EfficiencyTypeVoltage - Output 3Power (Watts)Current - Output 5Voltage - Output 1Voltage - Output 6Current - Output 4Cooling TypeVoltage - Input [Min]Voltage - Input [Max]HeightHeight [z]Input ConnectorNumber of PositionsFeaturesCurrent - Leakage
coolx1000-fr-wp
EXCELSYS / Advanced Energy
4.17 A
ITE (Commercial)
Medical
24 V
7
60601-1
60950-1
62368-1
CSA
EN
IEC
UL
85 °C
-40 C
Adjustable Output
PMBus™
Remote Sense
Standby Output
Universal Input
3 A
48 V
4000 V
6 A
8.3 A
24 V
Chassis Mount
10.22 in
259.5 mm
1.6 "
164 mm
6.46 in
40.6 mm
93 %
Enclosed
48 V
1 kW
4.17 A
5 V
24 V
8.3 A
coolx1000-fr-wp
EXCELSYS / Advanced Energy
4.17 A
ITE (Commercial)
Medical
5 V
6
60601-1
60950-1
62368-1
CSA
EN
IEC
UL
85 °C
-40 C
Adjustable Output
PMBus™
Remote Sense
Standby Output
Universal Input
15 A
24 V
4000 V
4.17 A
4.17 A
12 V
Chassis Mount
10.22 in
259.5 mm
1.6 "
164 mm
6.46 in
40.6 mm
93 %
Enclosed
48 V
880 W
3 A
48 V
48 V
6 A
coolx1000-fr-wp
EXCELSYS / Advanced Energy
15 A
ITE (Commercial)
Medical
24 V
8
60601-1
60950-1
62368-1
CSA
EN
IEC
UL
85 °C
-40 C
Adjustable Output
PMBus™
Remote Sense
Standby Output
Universal Input
3 A
5 V
4000 V
6 A
3 A
24 V
Chassis Mount
10.22 in
259.5 mm
1.6 "
164 mm
6.46 in
40.6 mm
93 %
Enclosed
12 V
980 W
6 A
5 V
24 V
8.3 A
coolx1000-fr-wp
EXCELSYS / Advanced Energy
4.17 A
ITE (Commercial)
Medical
7
60601-1
60950-1
62368-1
CSA
EN
IEC
UL
85 °C
-40 C
Adjustable Output
PMBus™
Remote Sense
Standby Output
Universal Input
4.17 A
48 V
4000 V
4.17 A
6 A
48 V
Chassis Mount
10.22 in
259.5 mm
1.6 "
164 mm
6.46 in
40.6 mm
93 %
Enclosed
48 V
1 kW
4.17 A
48 V
5 V
4.17 A
CX10M-000000-N-B
EXCELSYS / Advanced Energy
60601-1
60950-1
62368-1
CSA
EN
IEC
UL
85 °C
-40 °C
4000 V
254 mm
165.1 mm
93 %
Medical
1 kW
Convection
85 VAC
120 VDC
264 VAC
300 V
25.4 mm
1 "
IEC 320-C14
6
4.7 A
5 V
500 µA
coolx1000-fr-wp
EXCELSYS / Advanced Energy
6 A
ITE (Commercial)
Medical
24 V
11
60601-1
60950-1
62368-1
CSA
EN
IEC
UL
85 °C
-40 C
Adjustable Output
PMBus™
Remote Sense
Standby Output
Universal Input
3 A
24 V
4000 V
3 A
3 A
24 V
Chassis Mount
10.22 in
259.5 mm
1.6 "
164 mm
6.46 in
40.6 mm
93 %
Enclosed
5 V
780 W
3 A
24 V
24 V
3 A
coolx1000-fr-wp
EXCELSYS / Advanced Energy
4.17 A
ITE (Commercial)
Medical
5 V
7
60601-1
60950-1
62368-1
CSA
EN
IEC
UL
85 °C
-40 C
Adjustable Output
PMBus™
Remote Sense
Standby Output
Universal Input
4.17 A
24 V
4000 V
4.17 A
4.17 A
48 V
Chassis Mount
10.22 in
259.5 mm
1.6 "
164 mm
6.46 in
40.6 mm
93 %
Enclosed
48 V
1 kW
3 A
48 V
48 V
6 A
coolx1000-fr-wp
EXCELSYS / Advanced Energy
4.17 A
ITE (Commercial)
Medical
24 V
9
60601-1
60950-1
62368-1
CSA
EN
IEC
UL
85 °C
-40 C
Adjustable Output
PMBus™
Remote Sense
Standby Output
Universal Input
4.17 A
24 V
4000 V
4.17 A
6 A
48 V
Chassis Mount
10.22 in
259.5 mm
1.6 "
164 mm
6.46 in
40.6 mm
93 %
Enclosed
48 V
920 W
3 A
48 V
5 V
3 A
coolx1000-fr-wp
EXCELSYS / Advanced Energy
3 A
ITE (Commercial)
Medical
5 V
11
60601-1
60950-1
62368-1
CSA
EN
IEC
UL
85 °C
-40 C
Adjustable Output
PMBus™
Remote Sense
Standby Output
Universal Input
3 A
24 V
4000 V
8.3 A
3 A
24 V
Chassis Mount
10.22 in
259.5 mm
1.6 "
164 mm
6.46 in
40.6 mm
93 %
Enclosed
24 V
780 W
3 A
24 V
24 V
6 A
coolx1000-fr-wp
EXCELSYS / Advanced Energy
4.17 A
ITE (Commercial)
Medical
5 V
9
60601-1
60950-1
62368-1
CSA
EN
IEC
UL
85 °C
-40 C
Adjustable Output
PMBus™
Remote Sense
Standby Output
Universal Input
3 A
24 V
4000 V
6 A
4.17 A
24 V
Chassis Mount
10.22 in
259.5 mm
1.6 "
164 mm
6.46 in
40.6 mm
93 %
Enclosed
48 V
900 W
3 A
5 V
48 V
6 A

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyN/A 0$ 0.00

Description

General part information

CX10S Series

Enclosed AC DC Converters 8 Output 5V 24V 12V 24V 85 ~ 264 VAC Input

Documents

Technical documentation and resources