Zenode.ai Logo
Beta
WSON (DSG)
Integrated Circuits (ICs)

INA351AIDSGR

Active
Texas Instruments

LOW-POWER (110 ΜA) INSTRUMENTATION AMPLIFIER WITH INTEGRATED REFERENCE AMP TO ENABLE CALIBRATION

Deep-Dive with AI

Search across all available documentation for this part.

WSON (DSG)
Integrated Circuits (ICs)

INA351AIDSGR

Active
Texas Instruments

LOW-POWER (110 ΜA) INSTRUMENTATION AMPLIFIER WITH INTEGRATED REFERENCE AMP TO ENABLE CALIBRATION

Technical Specifications

Parameters and characteristics for this part

SpecificationINA351AIDSGR
-3db Bandwidth100 kHz
Amplifier TypeInstrumentation
Current - Input Bias0.75 pA
Current - Output / Channel20 mA
Current - Supply110 µA
Gain Bandwidth Product360 kHz
Mounting TypeSurface Mount
Number of Circuits1
Operating Temperature [Max]125 °C
Operating Temperature [Min]-40 °C
Output TypeSingle-Ended
Package / Case8-WFDFN Exposed Pad
Slew Rate0.2 V/µs
Supplier Device Package8-WSON (2x2)
Voltage - Input Offset200 çV
Voltage - Supply Span (Max) [Max]5.5 V
Voltage - Supply Span (Min) [Min]1.8 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyCut Tape (CT) 1$ 0.72
10$ 0.63
25$ 0.59
100$ 0.49
250$ 0.45
500$ 0.38
1000$ 0.31
Digi-Reel® 1$ 0.72
10$ 0.63
25$ 0.59
100$ 0.49
250$ 0.45
500$ 0.38
1000$ 0.31
Tape & Reel (TR) 3000$ 0.28
6000$ 0.26
15000$ 0.25
30000$ 0.24
Texas InstrumentsLARGE T&R 1$ 0.55
100$ 0.37
250$ 0.29
1000$ 0.19

Description

General part information

INA351A Series

INA351A is a fixed gain of 10 instrumentation amplifier with a configurable reference amplifier in a small package. This instrumentation amp (INA) is built with precision-matched resistors to achieve excellent CMRR and gain error performance in a small, low-cost form factor. This makes INA351A a great solution to replace discrete INA implementations to achieve higher performance and more compact designs with minimal impact to bill of materials (BOM) costs.

The integrated, configurable reference amplifier can be used as a buffer for external use or as part of a closed-loop calibration circuit to achieve better DC precision. The closed-loop calibration can be accomplished by implementing a servo loop amplifier to calibrate DC errors from sensors (like offset, offset drift and so forth) at the INA output when the INA input signal is at a slightly higher frequency than DC depending on the application.

INA351A achieves 86 dB of minimum CMRR, an accurate 0.1% of maximum gain error and only consumes a maximum of 135 µA quiescent current at room temperature. The INA can directly drive sub-1 kHz, 10-bit to 14-bit, delta-sigma analog-to-digital converters (ADC) without an ADC driver, making it a great choice for portable, battery-powered medical applications like electrocardiograms or wearable health monitors.