MAX30009ENA+
ActiveLOW-POWER, HIGH-PERFORMANCE BIOIMPEDANCE ANALOG FRONT-END
Deep-Dive with AI
Search across all available documentation for this part.

MAX30009ENA+
ActiveLOW-POWER, HIGH-PERFORMANCE BIOIMPEDANCE ANALOG FRONT-END
Technical Specifications
Parameters and characteristics for this part
| Specification | MAX30009ENA+ |
|---|---|
| Mounting Type | Surface Mount |
| Number of Bits | 20 |
| Number of Channels | 2 |
| Package / Case | 25-XFBGA, WLBGA |
| Supplier Device Package | 25-WLP |
| Supplier Device Package [x] | 2.03 |
| Supplier Device Package [y] | 2.03 |
| Voltage - Supply, Analog [Max] | 2 V |
| Voltage - Supply, Analog [Min] | 1.7 V |
| Voltage - Supply, Digital [Max] | 2 V |
| Voltage - Supply, Digital [Min] | 1.7 V |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
| Distributor | Package | Quantity | $ | |
|---|---|---|---|---|
| Digikey | N/A | 0 | $ 12.52 | |
| 5650 | $ 12.52 | |||
| Strip | 1 | $ 13.24 | ||
| 10 | $ 9.37 | |||
| 25 | $ 8.37 | |||
| 100 | $ 7.26 | |||
| 250 | $ 6.72 | |||
| 500 | $ 6.39 | |||
| 1000 | $ 6.19 | |||
Description
General part information
MAX30009 Series
The MAX30009 is a complete Bioimpedance (BioZ) Analog Front-End (AFE) solution for wearable applications. It offers high performance for fitness, wellness, and clinical applications, and ultra-low power for long battery life. The BioZ receive channel has Electrostatic Discharge (ESD) protection, Electromagnetic Interference (EMI) filtering, internal lead-biasing, DC leads-off detection, DRVN lead-off detection, and ultra-low power lead-on detection during standby mode. The BioZ receive channel also has high input impedance, low noise, high Common-Mode Rejection Ratio (CMRR), programmable gain, various low-pass and high-pass filter options, and two high resolution analog-to-digital converters for simultaneous I and Q acquisition.The BioZ transmit channel has a sine-wave current generator to drive AC currents into the body with a wide frequency range of 16Hz to 500kHz and a wide magnitude range of of 16nARMSto 1.28mARMS. The transmit channel can also operate in the sine-wave voltage and H-bridge modes. The flexible input/output MUX allows for both bipolar and tetrapolar measurements with multiple sets of electrodes.For measurements requiring high absolute impedance accuracy such as Bioimpedance Analysis/Spectroscopy (BIA/BIS) and Automated External Defibrillator (AED) body impedance, the MAX30009 offers several calibration options. An external precision resistor can be connected to the four-wire calibration port for the highest accuracy. Internal trimmed resistors also provide high accuracy.The PLL-based timing subsystem allows for a wide range of fine-tuned stimulus and sampling frequencies, and can be synchronized with other Analog Devices biosensors for simultaneous data collection.The MAX30009 is available in a 2.03mm x 2.03mm, 25-bump Wafer-Level Package (WLP), operating over the -40°C to +85°C temperature range.ApplicationsWearable Fitness, Wellness, and Medical DevicesMultifrequency Body Composition AnalyzersNon-Invasive Hemodynamic MonitorsAutomatic External DefibrillatorsOptimized Performance to Accurately Detect:Respiration RateGalvanic Skin Response/Electrodermal ActivityBioimpedance SpectroscopyBody Composition and Fluid AnalysisImpedance Cardiography and Plethysmography