Technical Specifications
Parameters and characteristics for this part
| Specification | MAX6648MUA+ |
|---|---|
| Accuracy - Highest (Lowest) | 2 °C, 3 °C |
| Features | One-Shot, Standby Mode, Programmable Limit, Output Switch |
| Mounting Type | Surface Mount |
| Operating Temperature [Max] | 125 °C |
| Operating Temperature [Min] | -55 C |
| Output Type | SMBus |
| Package / Case | 8-TSSOP, 8-MSOP |
| Package / Case | 0.118 in, 3 mm Width |
| Resolution | 10 b |
| Sensing Temperature - Local [Max] | 125 °C |
| Sensing Temperature - Local [Min] | 0 °C |
| Sensing Temperature - Remote [Max] | 125 °C |
| Sensing Temperature - Remote [Min] | 0 °C |
| Supplier Device Package | 8-uMAX/uSOP |
| Test Condition [Max] | 100 |
| Test Condition [Min] | 60 |
| Voltage - Supply [Max] | 5.5 V |
| Voltage - Supply [Min] | 3 V |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
| Distributor | Package | Quantity | $ | |
|---|---|---|---|---|
| Digikey | N/A | 10 | $ 5.21 | |
| 4100 | $ 5.21 | |||
| Tube | 1 | $ 5.89 | ||
| 5 | $ 4.97 | |||
| 10 | $ 4.61 | |||
| 25 | $ 4.19 | |||
| 50 | $ 3.89 | |||
| 100 | $ 3.62 | |||
| 500 | $ 3.05 | |||
| 1000 | $ 2.84 | |||
Description
General part information
MAX6648 Series
The MAX6648/MAX6692 are precise, two-channel digital temperature sensors. They accurately measure the temperature of their own die and a remote PN junction, and report the temperature in digital form using a 2-wire serial interface. The remote PN junction is typically the emitter-base junction of a common-collector PNP on a CPU, FPGA, or ASIC.The 2-wire serial interface accepts standard System Management Bus (SMBus™) write byte, read byte, send byte, and receive byte commands to read the temperature data and to program the alarm thresholds. To enhance system reliability, the MAX6648/MAX6692 include an SMBus timeout. A fault queue prevents the active-low ALERT and active-low OVERT outputs from setting until a fault has been detected one, two, or three consecutive times (programmable).The MAX6648/MAX6692 provide two system alarms: active-low ALERT and active-low OVERT. Active-low ALERT asserts when any of four temperature conditions are violated: local overtemperature, remote overtemperature, local undertemperature, or remote undertemperature. Active-low OVERT asserts when the temperature rises above the value in either of the two active-low OVERT limit registers. The active-low OVERT output can be used to activate a cooling fan, or to trigger a system shutdown.Measurements can be done autonomously, with the conversion rate programmed by the user, or in a single-shot mode. The adjustable conversion rate allows the user to optimize supply current and temperature update rate to match system needs.Remote accuracy is ±0.8°C maximum error between +25°C and +125°C with no calibration needed. The MAX6648/MAX6692 operate from -55°C to +125°C, and measure temperatures between 0°C and +125°C. The MAX6648 is available in an 8-pin µMAX® package, and the MAX6692 is available in 8-pin µMAX and SO packages.ApplicationsDesktop ComputersMultichip ModulesNotebook ComputersServersTest and Measurement EquipmentThin ClientsWorkstations