Zenode.ai Logo
Beta
14-WFDFN Exposed Pad
Integrated Circuits (ICs)

LMP91002SD/NOPB

Obsolete
Texas Instruments

CONFIGURABLE AFE FOR LOW POWER H2S AND CO SENSING APPLICATIONS

14-WFDFN Exposed Pad
Integrated Circuits (ICs)

LMP91002SD/NOPB

Obsolete
Texas Instruments

CONFIGURABLE AFE FOR LOW POWER H2S AND CO SENSING APPLICATIONS

Technical Specifications

Parameters and characteristics for this part

SpecificationLMP91002SD/NOPB
Mounting TypeSurface Mount
Number of Bits8
Number of Channels1
Package / Case14-WFDFN Exposed Pad
Supplier Device Package14-WSON (4x4)
Voltage - Supply, Analog [Max]3.6 V
Voltage - Supply, Analog [Min]2.7 V
Voltage - Supply, Digital [Max]3.6 V
Voltage - Supply, Digital [Min]2.7 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyCut Tape (CT) 1$ 6.20
10$ 4.18
25$ 3.66
100$ 3.08
250$ 2.79
500$ 2.62
Digi-Reel® 1$ 6.20
10$ 4.18
25$ 3.66
100$ 3.08
250$ 2.79
500$ 2.62
Tape & Reel (TR) 1000$ 2.59
2000$ 2.46
Texas InstrumentsSMALL T&R 1$ 3.71
100$ 3.25
250$ 2.28
1000$ 1.83

Description

General part information

LMP91002 Series

The LMP91002 device is a programmable Analog Front End (AFE) for use in micro-power electrochemical-sensing applications. It provides a complete signal path solution between a not biased gas sensor and a microcontroller generating an output voltage proportional to the cell current.

The LMP91002’s programmability enables it support not biased electro-chemical gas sensor with a single design. The LMP91002 supports gas sensitivities over a range of 0.5 nA/ppm to 9500 nA/ppm. It also allows for an easy conversion of current ranges from 5 µA to 750 µA full scale. The LMP91002’s transimpedance amplifier (TIA) gain is programmable through the I2C interface. The I2C interface can also be used for sensor diagnostics. The LMP91002 is optimized for micro-power applications and operates over a voltage range of 2.7 V to 3.6 V. The total current consumption can be less than 10 µA. Further power savings are possible by switching off the TIA amplifier and shorting the reference electrode to the working electrode with an internal switch.

The LMP91002 device is a programmable Analog Front End (AFE) for use in micro-power electrochemical-sensing applications. It provides a complete signal path solution between a not biased gas sensor and a microcontroller generating an output voltage proportional to the cell current.