Zenode.ai Logo
Beta
SOIC (DWV)
Integrated Circuits (ICs)

AMC1301DWV

Active
Texas Instruments

±250 MV-INPUT PRECISION REINFORCED ISOLATED AMPLIFIER FOR CURRENT SENSING

SOIC (DWV)
Integrated Circuits (ICs)

AMC1301DWV

Active
Texas Instruments

±250 MV-INPUT PRECISION REINFORCED ISOLATED AMPLIFIER FOR CURRENT SENSING

Technical Specifications

Parameters and characteristics for this part

SpecificationAMC1301DWV
Amplifier TypeIsolation
Current - Input Bias60 µA
Current - Output / Channel13 mA
Current - Supply5.9 mA
Gain Bandwidth Product1 MHz
Mounting TypeSurface Mount
Number of Circuits1
Operating Temperature [Max]125 °C
Operating Temperature [Min]-40 °C
Package / Case8-SOIC
Package / Case [custom]0.295 in
Package / Case [custom]7.5 mm
Supplier Device Package8-SOIC
Voltage - Input Offset50 µV
Voltage - Supply Span (Max) [Max]5.5 V
Voltage - Supply Span (Min) [Min]3 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyTube 1$ 9.83
10$ 8.88
64$ 8.47
128$ 7.35
256$ 7.02
512$ 6.40
1024$ 5.58
Texas InstrumentsTUBE 1$ 8.26
100$ 7.24
250$ 5.08
1000$ 4.09

Description

General part information

AMC1301-Q1 Series

The AMC1301-Q1 is a precision, isolated amplifier with an output separated from the input circuitry by an isolation barrier that is highly resistant to magnetic interference. This barrier is certified to provide reinforced isolation of up to 7070 V PEAK according to the DIN EN IEC 60747-17 (VDE 0884-17) and UL1577 standards, and supports a working voltage up to 1 kV RMS.

The isolation barrier separates parts of the system that operate on different common-mode voltage levels and protects the low-side from voltage levels that can cause electrical damage and are potentially harmful to an operator.

The input of the AMC1301-Q1 is optimized for direct connection to shunt resistors or other low voltage-level signal sources. The excellent DC accuracy and low temperature drift supports accurate current control in onboard chargers (OBC), DC/DC converters, frequency inverters, or other high-voltage applications. The integrated common-mode overvoltage and missing high-side supply voltage detection features of the AMC1301-Q1 simplify system-level design and diagnostics.

Documents

Technical documentation and resources

Isolated Voltage-Measurement Circuit With ±250-mV Input and Differential Output (Rev. A)

Application note

Isolated current-measurement circuit with ±250-mV input and differential output

Circuit design

For efficiencies’ sake – how to integrate bidirectional power flow (part 2)

Technical article

Pile on to a charger – my EV needs power

Technical article

CQC Certificate for AMC13xx: Taiwan

Certificate

How to reduce system cost in a three-phase IGBT-based inverter design

Technical article

Isolierte Spannungsmessschaltung mit ±250 mV-Eingang und Differenzausgang (Rev. A)

Application note

High Voltage Isolation Quality and Reliability for AMC130x

White paper

±250mV 입력 및 차동 출력을 사용하는 절연 전압 측정 회로 (Rev. A)

Application note

±250mV 입력 및 차동 출력을 지원하는 절연 전류 측정 회로

Circuit design

UL Certificate of Compliance Vol4 Sec5 E181974 (Rev. A)

Certificate

Anschluss eines Differenzialausgangsverstärkers (isoliert) an einen A/D-Wandler mit unsymmetrischem Eingang (Rev. B)

Application brief

Covering wide analog input measurement for grid protection and control using 24-bi

Technical article

±250mV 입력 범위 및 단일 종단 출력 전압을 지원하는 절연 전류 감 지 회로

Circuit design

Ein Leitfaden für Techniker zu isolierten Signalkettenlösungen

E-book

Designing a Bootstrap Charge-Pump Power Supply for an Isolated Amplifier

Application note

절연 데이터 컨버터를 위한 션트 레지스터 선택

Application brief

An Engineer's Guide to Isolated Signal Chain Solutions

E-book

Thermocouple Temperature Measurements Using Isolated Amplifiers (Rev. A)

Application brief

EVM User's Guide: AMC-AMP-50A-EVM (Rev. A)

EVM User's guide

Isolated Current-Sensing Circuit W/ ±250-mV Input Range & Single-Ended Output

Circuit design

Entwicklung einer Bootstrap-Ladepumpen-Stromversorgung für einen isolierten Verstärker

Application note

AMC1301 Precision, ±250-mV Input, Reinforced Isolated Amplifier datasheet (Rev. G)

Data sheet

절연 신호 체인 솔루션에 관한 엔지니어 가이드

E-book

Interfacing a Differential-Output (Isolated) Amp to a Single-Ended Input ADC (Rev. B)

Application brief

Understanding isolation terminology and relevance

Selection guide

Isolierte Strommessschaltung mit ±250 mV Eingangsbereich und unsymmetrischer Ausgangsspannung

Circuit design

For efficiencies’ sake – how to integrate bidirectional power flow into your UPS design (part 1)

Technical article

Understanding current sensing in HEV/EV batteries

Technical article

CQC Certificate for AMC13xx: Malaysia

Certificate

Shunt-Widerstandsauswahl für isolierte Datenwandler

Application brief

절연 증폭기를 위한 부트스트랩 충전 펌프 전원 공급 장치 설계

Application note

Isolierter Strommessschaltkreis mit ±250 mV-Eingang und Differenzausgang

Circuit design

단일 종단 입력 ADC에 차동 출력(절연) 증폭기 인터페이싱 (Rev. B)

Application brief

Shunt Resistor Selection for Isolated Data Converters

Application brief

AMC130x Evaluation Module User's Guide (Rev. C)

EVM User's guide