Power Supplies - External/Internal (Off-Board)
CUS400M-24/AX5
ActiveTDK-LAMBDA
AC/DC OPEN FRAME POWER SUPPLY (PSU), ITE & MEDICAL, 85V AC TO 264V AC, ADJUSTABLE, FIXED
Deep-Dive with AI
Search across all available documentation for this part.

Power Supplies - External/Internal (Off-Board)
CUS400M-24/AX5
ActiveTDK-LAMBDA
AC/DC OPEN FRAME POWER SUPPLY (PSU), ITE & MEDICAL, 85V AC TO 264V AC, ADJUSTABLE, FIXED
Deep-Dive with AI
Technical Specifications
Parameters and characteristics for this part
| Specification | CUS400M-24/AX5 |
|---|---|
| Applications | ITE (Commercial), Medical |
| Approval Agency | CE |
| Current - Output 1 | 10.42 A |
| Features | Universal Input, Standby Output, Remote On/Off, Remote Sense, Adjustable Output |
| Minimum Load Required | False |
| Mounting Type | Chassis Mount |
| Number of Outputs | 1 |
| Operating Temperature [Max] | 70 °C |
| Operating Temperature [Min] | -20 °C |
| Power (Watts) | 250 W |
| Power (Watts) | 400 W |
| Size / Dimension [x] | 142 mm |
| Size / Dimension [x] | 5.59 in |
| Size / Dimension [y] | 90 mm |
| Size / Dimension [y] | 3.54 in |
| Size / Dimension [z] | 42.5 mm |
| Size / Dimension [z] | 1.67 in |
| Standard Number | 60950-1, 60601-1, 62368-1 |
| Type | Enclosed |
| Voltage - Isolation | 4000 V |
| Voltage - Output 1 | 24 V |
CUS400M Series
| Part | Standard Number | Type | Applications | Operating Temperature [Min] | Operating Temperature [Max] | Approval Agency | Minimum Load Required | Mounting Type | Power (Watts) | Power (Watts) | Size / Dimension [z] | Size / Dimension [x] | Size / Dimension [x] | Size / Dimension [y] | Size / Dimension [y] | Size / Dimension [z] | Voltage - Isolation | Current - Output 1 | Features | Voltage - Output 1 | Number of Outputs |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() TDK-LAMBDA | 60601-1 60950-1 62368-1 | Enclosed | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 42.5 mm | 142 mm | 5.59 in | 90 mm | 3.54 in | 1.67 in | 4000 V | 10.42 A | Adjustable Output Remote On/Off Remote Sense Standby Output Universal Input | 24 V | 1 | |
![]() TDK-LAMBDA | 60601-1 60950-1 62368-1 | Enclosed | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 42.5 mm | 142 mm | 5.59 in | 90 mm | 3.54 in | 1.67 in | 4000 V | 10.42 A | Adjustable Output Remote Sense Standby Output Universal Input | 24 V | 1 | |
![]() TDK-LAMBDA | 60601-1 62368-1 | Enclosed | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 42.5 mm | 142 mm | 5.59 in | 90 mm | 3.54 in | 1.67 in | 4000 V | 6.94 A | Adjustable Output PFC Remote Sense Universal Input | 36 V | 1 | |
![]() TDK-LAMBDA | 60601-1 62368-1 | Enclosed | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 67.5 mm | 142 mm | 5.59 in | 90 mm | 3.54 in | 2.66 " | 4000 V | Adjustable Output PFC Remote Sense Universal Input | 19 V | 1 | ||
![]() TDK-LAMBDA | 60601-1 62368-1 | Open Frame | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 40.8 mm | 141.6 mm | 5.57 in | 85.3 mm | 3.36 " | 1.61 " | 4000 V | Adjustable Output Baseplate PFC Remote Sense Universal Input | 19 V | 1 | ||
![]() TDK-LAMBDA | 60601-1 60950-1 62368-1 | Enclosed | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 67.5 mm | 142 mm | 5.59 in | 90 mm | 3.54 in | 2.66 " | 4000 V | 20.83 A | Adjustable Output Remote Sense Standby Output Universal Input | 12 V | 1 | |
![]() TDK-LAMBDA | 60601-1 60950-1 62368-1 | Enclosed | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 42.5 mm | 142 mm | 5.59 in | 90 mm | 3.54 in | 1.67 in | 4000 V | 20.83 A | Adjustable Output Remote Sense Standby Output Universal Input | 12 V | 1 | |
![]() TDK-LAMBDA | 60601-1 62368-1 | Open Frame | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 40.8 mm | 141.6 mm | 5.57 in | 85.3 mm | 3.36 " | 1.61 " | 4000 V | Adjustable Output Baseplate PFC Remote Sense Universal Input | 19 V | 1 | ||
![]() TDK-LAMBDA | 60601-1 62368-1 | Open Frame | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 41 mm | 142 mm | 5.59 in | 90 mm | 3.54 in | 1.61 " | 4000 V | 16.67 A | Adjustable Output PFC Remote Sense Universal Input | 15 V | 1 | |
![]() TDK-LAMBDA | 60601-1 62368-1 | Open Frame | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 40.8 mm | 141.6 mm | 5.57 in | 85.3 mm | 3.36 " | 1.61 " | 4000 V | 6.94 A | Adjustable Output Baseplate PFC Remote Sense Universal Input | 36 V | 1 |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
Description
General part information
CUS400M Series
Enclosed AC DC Converters 1 Output 24V 85 ~ 264 VAC Input
Documents