ADR1399KHZ
Integrated Circuits (ICs)

ADR1399KHZ

Active
Analog Devices Inc./Maxim Integrated

OVEN-COMPENSATED, BURIED ZENER, 7.05 V VOLTAGE REFERENCE

Deep-Dive with AI

Search across all available documentation for this part.

ADR1399KHZ
Integrated Circuits (ICs)

ADR1399KHZ

Active
Analog Devices Inc./Maxim Integrated

OVEN-COMPENSATED, BURIED ZENER, 7.05 V VOLTAGE REFERENCE

Technical Specifications

Parameters and characteristics for this part

SpecificationADR1399KHZ
Current - Output20 mA
Current - Supply3 mA
Mounting TypeThrough Hole
Noise1.44 µVp-p, 1.84 µVrms
Operating Temperature (Max)70 °C
Operating Temperature (Min)0 °C
Output TypeFixed
Package / CaseTO-46-4 Metal Can
Package NameTO-46-4
Reference TypeBuried Zener, Shunt
Temperature Coefficient1 ppm/°C
Tolerance0.05 %
Voltage - Output (Min/Fixed)7.05 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$Updated
DigikeyTube 1$ 26.13<1d
20$ 20.04
40$ 19.22
100$ 18.36
260$ 17.67
500$ 17.29

CAD

3D models and CAD resources for this part

Description

General part information

ADR1399 Series

The ADR1399 precision shunt reference features excellent temperature stability over a wide range of voltage, temperature, and quiescent current conditions. A temperature stabilizing loop is incorporated with the active Zener on a monolithic substrate, which nearly eliminates changes in voltage with temperature. The subsurface Zener circuit is fully specified at a quiescent current IREFof 3 mA and offers minimal noise (1.44 μV p-p, 0.1 Hz to 10 Hz) and excellent long-term stability (7 ppm/√kHr). The ADR1399 offers a lower output dynamic impedance (0.08 Ω) than the LM399, reducing the effects of shunt resistor (RSHUNT) and the supply voltage variation on the reference output.Ideal applications for the ADR1399 include ultrastable digital voltmeters, precision calibration equipment, and ultrarepeatable analog-to-digital converters (ADCs). The simplicity of the basic pin configurations is shown in Figure 1. The 8-terminal LCC version offers force and sense pins for lower dynamic impedance and for Kelvin sensing.Table 1. Related ProductsModelOutput Voltage (V)Initial Accuracy Range (mV)ADR13997.05–300 to +250LTZ10007.2–200 to +300LM3996.95–200 to +350LT12365 and 10–2.5 to +2.5APPLICATIONSPrecision voltage reference for multimetersCalibration equipment voltage standardsLaboratory measurement equipmentIndustrial monitor and control instrumentationUltrastable data convertors