Power Supplies - External/Internal (Off-Board)
LFMWLT200-1305
ActiveBel Fuse Inc.
AC/DC CONVERTER 30V 160W
Deep-Dive with AI
Search across all available documentation for this part.
DocumentsLFMWLT200-1305 | Datasheet

Power Supplies - External/Internal (Off-Board)
LFMWLT200-1305
ActiveBel Fuse Inc.
AC/DC CONVERTER 30V 160W
Deep-Dive with AI
DocumentsLFMWLT200-1305 | Datasheet
Technical Specifications
Parameters and characteristics for this part
| Specification | LFMWLT200-1305 |
|---|---|
| Applications | Medical |
| Approval Agency | CE, NEMKO, UL, CB, cUL |
| Current - Output 1 | 5.33 A |
| Efficiency | 86 % |
| Features | PFC, Remote On/Off, Universal Input, Remote Sense, Standby Output, DC Input Capable, Adjustable Output |
| Minimum Load Required | False |
| Mounting Type | Chassis Mount |
| Number of Outputs | 1 |
| Operating Temperature [Max] | 70 °C |
| Operating Temperature [Min] | -20 °C |
| Power (Watts) | 200 W, 160 W |
| Size / Dimension [x] | 127 mm |
| Size / Dimension [x] | 5 " |
| Size / Dimension [y] | 76.2 mm |
| Size / Dimension [y] | 3 " |
| Size / Dimension [z] | 1.5 in |
| Size / Dimension [z] | 38.1 mm |
| Type | Enclosed |
| Voltage - Input [Max] | 264 VAC, 390 VDC |
| Voltage - Input [Min] | 90 VAC, 120 VDC |
| Voltage - Isolation | 5.9 kV |
| Voltage - Output 1 | 30 V |
| Part | Mounting Type | Voltage - Input [Min] | Voltage - Input [Max] | Features | Type | Applications | Voltage - Output 1 | Current - Output 1 | Efficiency | Power (Watts) | Power (Watts) | Number of Outputs | Operating Temperature [Max] | Operating Temperature [Min] | Voltage - Isolation | Size / Dimension [y] | Size / Dimension [x] | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [x] | Size / Dimension [z] | Approval Agency | Minimum Load Required |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bel Fuse Inc. | Chassis Mount | 90 VAC 120 VDC | 264 VAC 390 VDC | Adjustable Output DC Input Capable PFC Remote On/Off Remote Sense Standby Output Universal Input | Enclosed | Medical | 5 V | 16.67 A | 86 % | 83 W | 130 W | 1 | 70 °C | -20 °C | 5.9 kV | 76.2 mm | 127 mm | 1.5 in | 3 " | 5 " | 38.1 mm | CB CE cUL NEMKO UL | |
Bel Fuse Inc. | Chassis Mount | 90 VAC 120 VDC | 264 VAC 390 VDC | Adjustable Output PFC Remote On/Off Remote Sense Standby Output Universal Input | Enclosed | Medical | 12 V | 13.33 A | 86 % | 160 W 200 W | 1 | 70 °C | -20 °C | 5.9 kV | 76.2 mm | 127 mm | 1.5 in | 3 " | 5 " | 38.1 mm | CB CE cUL NEMKO UL | ||
Bel Fuse Inc. | Chassis Mount | 90 VAC 120 VDC | 264 VAC 390 VDC | Adjustable Output DC Input Capable PFC Remote On/Off Remote Sense Standby Output Universal Input | Enclosed | Medical | 24 V | 6.67 A | 86 % | 160 W 200 W | 1 | 70 °C | -20 °C | 5.9 kV | 76.2 mm | 127 mm | 1.5 in | 3 " | 5 " | 38.1 mm | CB CE cUL NEMKO UL | ||
Bel Fuse Inc. | Chassis Mount | 90 VAC 120 VDC | 264 VAC 390 VDC | Adjustable Output DC Input Capable PFC Remote On/Off Remote Sense Standby Output Universal Input | Enclosed | Medical | 5 V | 16.67 A | 86 % | 83 W | 130 W | 1 | 70 °C | -20 °C | 5.9 kV | 76.2 mm | 127 mm | 1.5 in | 3 " | 5 " | 38.1 mm | CB CE cUL NEMKO UL | |
Bel Fuse Inc. | Chassis Mount | 90 VAC 120 VDC | 264 VAC 390 VDC | Adjustable Output DC Input Capable PFC Remote On/Off Remote Sense Standby Output Universal Input | Enclosed | Medical | 15 V | 10.67 A | 86 % | 160 W 200 W | 1 | 70 °C | -20 °C | 5.9 kV | 76.2 mm | 127 mm | 1.5 in | 3 " | 5 " | 38.1 mm | CB CE cUL NEMKO UL | ||
Bel Fuse Inc. | Chassis Mount | 90 VAC 120 VDC | 264 VAC 390 VDC | Adjustable Output DC Input Capable PFC Remote On/Off Remote Sense Standby Output Universal Input | Enclosed | Medical | 24 V | 6.67 A | 86 % | 160 W 200 W | 1 | 70 °C | -20 °C | 5.9 kV | 76.2 mm | 127 mm | 1.5 in | 3 " | 5 " | 38.1 mm | CB CE cUL NEMKO UL | ||
Bel Fuse Inc. | Chassis Mount | 90 VAC 120 VDC | 264 VAC 390 VDC | Adjustable Output DC Input Capable PFC Remote On/Off Remote Sense Standby Output Universal Input | Enclosed | Medical | 30 V | 5.33 A | 86 % | 160 W 200 W | 1 | 70 °C | -20 °C | 5.9 kV | 76.2 mm | 127 mm | 1.5 in | 3 " | 5 " | 38.1 mm | CB CE cUL NEMKO UL | ||
Bel Fuse Inc. | Chassis Mount | 90 VAC 120 VDC | 264 VAC 390 VDC | Adjustable Output DC Input Capable PFC Remote On/Off Remote Sense Standby Output Universal Input | Enclosed | Medical | 5 V | 16.67 A | 86 % | 1 | 70 °C | -20 °C | 5.9 kV | 76.2 mm | 127 mm | 1.5 in | 3 " | 5 " | 38.1 mm | CB CE cUL NEMKO UL | |||
Bel Fuse Inc. | Chassis Mount | 90 VAC 120 VDC | 264 VAC 390 VDC | Adjustable Output DC Input Capable PFC Remote On/Off Remote Sense Standby Output Universal Input | Enclosed | Medical | 30 V | 5.33 A | 86 % | 160 W 200 W | 1 | 70 °C | -20 °C | 5.9 kV | 76.2 mm | 127 mm | 1.5 in | 3 " | 5 " | 38.1 mm | CB CE cUL NEMKO UL | ||
Bel Fuse Inc. | Chassis Mount | 90 VAC 120 VDC | 264 VAC 390 VDC | Adjustable Output DC Input Capable PFC Remote On/Off Remote Sense Standby Output Universal Input | Enclosed | Medical | 30 V | 5.33 A | 86 % | 160 W 200 W | 1 | 70 °C | -20 °C | 5.9 kV | 76.2 mm | 127 mm | 1.5 in | 3 " | 5 " | 38.1 mm | CB CE cUL NEMKO UL |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
| Distributor | Package | Quantity | $ | |
|---|---|---|---|---|
| Digikey | Bulk | 42 | $ 98.66 | |
| 42 | $ 98.66 | |||
| N/A | 0 | $ 101.56 | ||
| 0 | $ 101.56 | |||
Description
General part information
MWLT200 Series
Enclosed AC DC Converters 1 Output 30V 90 ~ 264 VAC, 120 ~ 390 VDC Input
Documents
Technical documentation and resources