Zenode.ai Logo
Beta
No image
Relays

MY2IN-GS AC100/110

Obsolete

Deep-Dive with AI

Search across all available documentation for this part.

DocumentsDatasheet
Relays

MY2IN-GS AC100/110

Obsolete

Deep-Dive with AI

DocumentsDatasheet

Technical Specifications

Parameters and characteristics for this part

SpecificationMY2IN-GS AC100/110
Approval AgencyVDE, CSA, UR, CE
Coil Current29.3 mA
Coil Resistance3.75 kOhms
Coil TypeNon Latching
Coil Voltage110 VAC/DC
Contact FormDPDT (2 Form C)
Contact MaterialSilver (Ag)
Contact Rating (Current)7 A
FeaturesLatching Lever
Load - Max Switching1750 VA, 1540 W
Mounting TypeSocketable
Must Operate Voltage88 VAC/DC
Must Release Voltage33 VAC
Operate Time20 ms
Operating Temperature [Max]70 °C
Operating Temperature [Min]-55 °C
Relay TypeGeneral Purpose
Release Time20 ms
Switching Voltage250 VAC, 220 VDC

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$

Description

General part information

MY2IN Series

General Purpose Relay DPDT (2 Form C) 110VAC Coil Socketable

Documents

Technical documentation and resources