REM2-0505S
ActiveISOLATED THROUGH HOLE DC/DC CONVERTER, MEDICAL, SIP, 1:1, 2 W, 1 OUTPUT, 5 V
Deep-Dive with AI
Search across all available documentation for this part.

REM2-0505S
ActiveISOLATED THROUGH HOLE DC/DC CONVERTER, MEDICAL, SIP, 1:1, 2 W, 1 OUTPUT, 5 V
Deep-Dive with AI
Technical Specifications
Parameters and characteristics for this part
| Specification | REM2-0505S |
|---|---|
| Applications | ITE (Commercial), Medical |
| Approval Agency | cURus, CB |
| Current - Output (Max) [Max] | 400 mA |
| Efficiency | 79 % |
| Features | OCP |
| Mounting Type | Through Hole |
| Number of Outputs | 1 |
| Operating Temperature [Max] | 95 °C |
| Operating Temperature [Min] | -40 °C |
| Package / Case | 8-SIP Module, 4 Leads |
| Power (Watts) | 2 W |
| Size / Dimension [x] | 0.91 " |
| Size / Dimension [x] | 23 mm |
| Size / Dimension [y] | 0.31 in |
| Size / Dimension [y] | 8 mm |
| Size / Dimension [z] | 0.48 " |
| Size / Dimension [z] | 12.2 mm |
| Type | Isolated Module |
| Voltage - Input (Max) [Max] | 5.5 V |
| Voltage - Input (Min) [Min] | 4.5 V |
| Voltage - Isolation | 5.2 kV |
| Voltage - Output 1 | 5 V |
| Part | Approval Agency | Operating Temperature [Max] | Operating Temperature [Min] | Number of Outputs | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [x] | Size / Dimension [x] | Mounting Type | Features | Voltage - Output 1 | Voltage - Input (Max) [Max] | Voltage - Output 2 | Applications | Power (Watts) | Voltage - Input (Min) [Min] | Package / Case | Voltage - Isolation | Type | Efficiency | Current - Output (Max) [Max] | Current - Output (Max) | Current - Output (Max) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Recom Power | CB cURus | 95 °C | -40 °C | 2 | 0.48 " | 0.31 in | 12.2 mm | 8 mm | 0.91 " | 23 mm | Through Hole | OCP | 5 V | 5.5 V | -5 V | ITE (Commercial) Medical | 2 W | 4.5 V | 8-SIP Module 5 Leads | 5.2 kV | Isolated Module | ||||
Recom Power | CB cURus | 95 °C | -40 °C | 1 | 0.48 " | 0.31 in | 12.2 mm | 8 mm | 0.91 " | 23 mm | Through Hole | OCP | 5 V | 5.5 V | ITE (Commercial) Medical | 2 W | 4.5 V | 8-SIP Module 4 Leads | 5.2 kV | Isolated Module | 79 % | 400 mA | |||
Recom Power | CB cURus | 95 °C | -40 °C | 2 | 0.48 " | 0.31 in | 12.2 mm | 8 mm | 0.91 " | 23 mm | Through Hole | OCP | 3.3 V | 5.5 V | -3.3 V | ITE (Commercial) Medical | 2 W | 4.5 V | 8-SIP Module 5 Leads | 5.2 kV | Isolated Module | 79 % | 303 mA | ||
Recom Power | CB cURus | 95 °C | -40 °C | 2 | 0.48 " | 0.31 in | 12.2 mm | 8 mm | 0.91 " | 23 mm | Through Hole | OCP | 5 V | 13.2 V | -5 V | ITE (Commercial) Medical | 2 W | 10.8 V | 8-SIP Module 5 Leads | 5.2 kV | Isolated Module | ||||
Recom Power | CB cURus | 95 °C | -40 °C | 2 | 0.48 " | 0.31 in | 12.2 mm | 8 mm | 0.91 " | 23 mm | Through Hole | OCP | 12 V | 26.4 V | -12 V | ITE (Commercial) Medical | 2 W | 21.6 V | 8-SIP Module 5 Leads | 5.2 kV | Isolated Module | 85 % | 84 mA | 84 mA | |
Recom Power | CB cURus | 95 °C | -40 °C | 1 | 0.48 " | 0.31 in | 12.2 mm | 8 mm | 0.91 " | 23 mm | Through Hole | OCP | 12 V | 26.4 V | ITE (Commercial) Medical | 2 W | 21.6 V | 8-SIP Module 4 Leads | 5.2 kV | Isolated Module | 167 mA | ||||
Recom Power | CB cURus | 95 °C | -40 °C | 2 | 0.48 " | 0.31 in | 12.2 mm | 8 mm | 0.91 " | 23 mm | Through Hole | OCP | 3.3 V | 16.5 V | -3.3 V | ITE (Commercial) Medical | 2 W | 13.5 V | 8-SIP Module 5 Leads | 5.2 kV | Isolated Module | 79 % | 303 mA | ||
Recom Power | CB cURus | 95 °C | -40 °C | 2 | 0.48 " | 0.31 in | 12.2 mm | 8 mm | 0.91 " | 23 mm | Through Hole | OCP | 5 V | 3.63 V | -5 V | ITE (Commercial) Medical | 2 W | 2.97 V | 8-SIP Module 5 Leads | 5.2 kV | Isolated Module | ||||
Recom Power | CB cURus | 95 °C | -40 °C | 1 | 0.48 " | 0.31 in | 12.2 mm | 8 mm | 0.91 " | 23 mm | Through Hole | OCP | 5 V | 3.63 V | ITE (Commercial) Medical | 2 W | 2.97 V | 8-SIP Module 4 Leads | 5.2 kV | Isolated Module | 79 % | 400 mA | |||
Recom Power | CB cURus | 95 °C | -40 °C | 1 | 0.48 " | 0.31 in | 12.2 mm | 8 mm | 0.91 " | 23 mm | Through Hole | OCP | 9 V | 26.4 V | ITE (Commercial) Medical | 2 W | 21.6 V | 8-SIP Module 4 Leads | 5.2 kV | Isolated Module | 84 % | 222 mA |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
Description
General part information
REM2 Series
Board mount REM2 series 2W single output unregulated converter complements the REM1 series by offering a 2W medical grade DC/DC converter in a compact SIP8 package. The REM2 features reinforced 5.2KVDC/1 minute isolation and 2MOPP/250VAC working voltage at 5000m. The operating temperature range is -40°C up to +80°C without derating, and up to +95°C with 50% load. The converter is compliant to Class A/B EMC and 60601-1-2 (4th Ed.) medical EMC using a simple external LC filter. The REM2 is certified to CB, IEC/EN and ANSI/AAMI 60601 third edition medical safety standards (pending) and comes with a 5 year warranty. Certifies by CAN/CSA-C22.2 No. 60601-1:14, ANSI/AAMI ES60601-1, IEC/EN60601-1, IEC/EN62368-1, EN60601-1-2, EN55011 and CB report.
Documents
Technical documentation and resources