HRV24AC
ActiveRELAY TIME DEL 31.75MIN 30A 125V

HRV24AC
ActiveRELAY TIME DEL 31.75MIN 30A 125V
Technical Specifications
Parameters and characteristics for this part
| Specification | HRV24AC |
|---|---|
| Contact Rating @ Voltage | 30 A |
| Contact Rating @ Voltage [Max] | 240 VAC |
| Contact Rating @ Voltage [Min] | 125 VAC |
| Delay Time [Max] | 31.75 Min |
| Delay Time [Min] | 0.25 Min |
| Function | Programmable (Multi-Function) |
| Mounting Type | Chassis Mount |
| Relay Type | Mechanical Relay |
| Termination Style | Quick Connect - 0.250" (6.3mm) |
| Timing Adjustment Method | DIP Switches |
| Timing Initiate Method | Input Voltage |
| Voltage - Supply | 24 VAC |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
Description
General part information
HRV24AC Series
The HRV combines the accuracy of microcontroller based circuitry with an electromechanical relay output. The HRV’s switching capacity allows direct control of loads like compressors, pumps, motors, heaters, and lighting. The HRV "S" version provides a vend time after the selected number of initiate switch closures to start is reached. The HRV "A" version includes all of the "S" features and allows the total vend time to be extended for each additional initiate switch closure. The HRV is ideal for cost sensitive single coin or token vending machines. The electronic circuitry is encapsulated to protect against humidity and vibration. OperationCoin Totalizer & Vending Timer ("S" Version): Input voltage must be applied prior to & during operation. When the total number of S1 initiate switch closures equals the number to start set on the lower 3 DIP switches, the load energizes and the vending time set on the upper 7 DIP switches begins. At the end of the vending time, the load de-energizes and the vending time is reset. Closing the initiate switch during vend timing will have no affect on vend time delay.Accumulating Vending Timer ("A" Version): Input voltage must be applied prior to & during operation. When the total number of S1 initiate switch closures equals the number to start set on the lower 3 DIP switches, the load energizes and the vending time starts. For every initiate switch closure, the HRV unit adds one time per coin period, as set on the upper 7 DIP switches, to the total vending time.Operation Note: If S1 is closed when input voltage is applied, the output remains de-energized and the S1 counter remains at zero closures. At least one "vend time" and one "closures to start" DIP switch must be in the "ON" position for proper operation.Reset: Removing input voltage resets the vend time delay, the S1 closure counter, and de-energizes the output relay.