FG-R02-4A
ActiveCURRENT SENSOR, ANALOGUE, DIGITAL OUTPUT, HORIZONTAL WITH BUSBAR, 20 MA AC, 6 MA DC, 4.75 TO 5.25 V
Deep-Dive with AI
Search across all available documentation for this part.

FG-R02-4A
ActiveCURRENT SENSOR, ANALOGUE, DIGITAL OUTPUT, HORIZONTAL WITH BUSBAR, 20 MA AC, 6 MA DC, 4.75 TO 5.25 V
Deep-Dive with AI
Technical Specifications
Parameters and characteristics for this part
| Specification | FG-R02-4A |
|---|---|
| Current - Sensing | 50 mA |
| Current - Supply (Max) | 13 mA |
| For Measuring | DC, AC |
| Frequency | 55 Hz |
| Mounting Type | Through Hole |
| Number of Channels [custom] | 1 |
| Operating Temperature [Max] | 105 ░C |
| Operating Temperature [Min] | -40 C |
| Output | Ratiometric, Voltage |
| Package / Case | Module, Single Pass Through |
| Polarization | Bidirectional |
| Response Time | 1 s, 250 ms |
| Sensitivity | 40 mV/g |
| Sensor Type | Flux Gate, Open Loop |
| Voltage - Supply [Max] | 5.25 V |
| Voltage - Supply [Min] | 4.75 V |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
Description
General part information
FG01/2/4/5 Series
FG-R02-4A sensor is a FG series high-sensitivity AC and DC leakage current sensor with individual open drain alarms and an analog output for leakage current indication. In addition, its integrated test coil can be initiated by a test input to perform a functional alarm test. Typical applications include residual current sensor for in-cable control and protection devices (IC-CPD) or wallbox.
Documents
Technical documentation and resources