Technical Specifications
Parameters and characteristics for this part
| Specification | TLC372CD |
|---|---|
| Current - Input Bias (Max) | 5 pA |
| Current - Output (Typ) | 20 mA |
| Current - Quiescent (Max) [Max] | 400 µA |
| Mounting Type | Surface Mount |
| Number of Elements | 2 |
| Operating Temperature [Max] | 70 °C |
| Operating Temperature [Min] | 0 °C |
| Output Type | TTL, MOS, Open-Drain, CMOS |
| Package / Case | 8-SOIC |
| Package / Case [x] | 0.154 in |
| Package / Case [y] | 3.9 mm |
| Supplier Device Package | 8-SOIC |
| Type | Differential |
| Voltage - Input Offset (Max) | 5 mV |
| Voltage - Supply, Single/Dual (±) [Max] | 8 V, 16 V |
| Voltage - Supply, Single/Dual (±) [Min] | -1.5 V, 3 V |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
| Distributor | Package | Quantity | $ | |
|---|---|---|---|---|
| Digikey | Tube | 1 | $ 2.22 | |
| 10 | $ 1.42 | |||
| 25 | $ 1.21 | |||
| Texas Instruments | TUBE | 1 | $ 1.13 | |
| 100 | $ 0.87 | |||
| 250 | $ 0.64 | |||
| 1000 | $ 0.46 | |||
Description
General part information
TLC372 Series
This device is fabricated using LinCMOS™ technology and consists of two independent voltage comparators, each designed to operate from a single power supply. Operation from dual supplies is also possible if the difference between the two supplies is 2 V to 18 V. Each device features extremely high input impedance (typically greater than 1012Ω), allowing direct interfacing with high-impedance sources. The outputs are n-channel open-drain configurations and can be connected to achieve positive-logic wired-AND relationships.
The TLC372 has internal electrostatic discharge (ESD) protection circuits and has been classified with a 1000-V ESD rating using human body model testing. However, care should be exercised in handling this device as exposure to ESD may result in a degradation of the device parametric performance.
The TLC372C is characterized for operation from 0°C to 70°C. The TLC372I is characterized for operation from –40°C to 85°C. The TLC372M is characterized for operation over the full military temperature range of –55°C to 125°C. The TLC372Q is characterized for operation from –40°C to 125°C.