Technical Specifications
Parameters and characteristics for this part
| Specification | LFWLT150-1002 |
|---|---|
| Applications | ITE (Commercial) |
| Approval Agency | CE, NEMKO, UL, CB, cUL |
| Current - Output 1 | 6.67 A |
| Efficiency | 86 % |
| Features | Adjustable Output, Universal Input, Standby Output, PFC |
| Minimum Load Required | False |
| Mounting Type | Chassis Mount |
| Number of Outputs | 1 |
| Operating Temperature [Max] | 70 °C |
| Operating Temperature [Min] | -20 °C |
| Power (Watts) | 100 W |
| Power (Watts) | 150 W |
| Size / Dimension [x] | 101.6 mm |
| Size / Dimension [x] | 4 " |
| Size / Dimension [y] | 50.8 mm |
| Size / Dimension [y] | 2 in |
| Size / Dimension [z] | 33.6 mm |
| Size / Dimension [z] | 1.32 in |
| Type | Open Frame |
| Voltage - Input [Max] | 264 VAC, 390 VDC |
| Voltage - Input [Min] | 90 VAC, 120 VDC |
| Voltage - Isolation | 4.242 kV |
| Voltage - Output 1 | 15 V |
| Part | Type | Number of Outputs | Operating Temperature [Max] | Operating Temperature [Min] | Minimum Load Required | Voltage - Input [Min] | Voltage - Input [Max] | Approval Agency | Voltage - Isolation | Voltage - Output 1 | Current - Output 1 | Mounting Type | Features | Efficiency | Size / Dimension [x] | Size / Dimension [z] | Size / Dimension [x] | Size / Dimension [y] | Size / Dimension [y] | Size / Dimension [z] | Power (Watts) | Applications | Power (Watts) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 90 VAC 120 VDC | 264 VAC 390 VDC | CB CE cUL NEMKO UL | 4.242 kV | 5 V | 16 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 101.6 mm | 33.6 mm | 4 " | 50.8 mm | 2 in | 1.32 in | 80 W 100 W | ITE (Commercial) | ||
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 90 VAC 120 VDC | 264 VAC 390 VDC | CB CE cUL NEMKO UL | 4.242 kV | 24 V | 4.17 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 101.6 mm | 33.6 mm | 4 " | 50.8 mm | 2 in | 1.32 in | 100 W | ITE (Commercial) | 150 W | |
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 90 VAC 120 VDC | 264 VAC 390 VDC | CB CE cUL NEMKO UL | 4.242 kV | 12 V | 8.33 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 101.6 mm | 33.6 mm | 4 " | 50.8 mm | 2 in | 1.32 in | 100 W | ITE (Commercial) | 150 W | |
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 90 VAC 120 VDC | 264 VAC 390 VDC | CB CE cUL NEMKO UL | 4.242 kV | 5 V | 16 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 101.6 mm | 33.6 mm | 4 " | 50.8 mm | 2 in | 1.32 in | 80 W | ITE (Commercial) | ||
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 90 VAC 120 VDC | 264 VAC 390 VDC | CB CE cUL NEMKO UL | 4.242 kV | 15 V | 6.67 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 101.6 mm | 33.6 mm | 4 " | 50.8 mm | 2 in | 1.32 in | 100 W | ITE (Commercial) | 150 W | |
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 90 VAC 120 VDC | 264 VAC 390 VDC | CB CE cUL NEMKO UL | 4.242 kV | 15 V | 6.67 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 101.6 mm | 33.6 mm | 4 " | 50.8 mm | 2 in | 1.32 in | 100 W | ITE (Commercial) | 150 W | |
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 90 VAC 120 VDC | 264 VAC 390 VDC | CB CE cUL NEMKO UL | 4.242 kV | 48 V | 2.08 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 101.6 mm | 33.6 mm | 4 " | 50.8 mm | 2 in | 1.32 in | 100 W | ITE (Commercial) | 150 W | |
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 90 VAC 120 VDC | 264 VAC 390 VDC | CB CE cUL NEMKO UL | 4.242 kV | 15 V | 6.67 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 101.6 mm | 33.6 mm | 4 " | 50.8 mm | 2 in | 1.32 in | 100 W | ITE (Commercial) | 150 W | |
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 90 VAC 120 VDC | 264 VAC 390 VDC | CB CE cUL NEMKO UL | 4.242 kV | 12 V | 8.33 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 101.6 mm | 33.6 mm | 4 " | 50.8 mm | 2 in | 1.32 in | 100 W | ITE (Commercial) | 150 W | |
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 90 VAC 120 VDC | 264 VAC 390 VDC | CB CE cUL NEMKO UL | 4.242 kV | 24 V | 4.17 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 101.6 mm | 33.6 mm | 4 " | 50.8 mm | 2 in | 1.32 in | 100 W | ITE (Commercial) | 150 W |