Zenode.ai Logo
Beta
RP40-FR
Power Supplies - Board Mount

RP40-4812SFR/N-HC

Active
Recom Power

ISOLATED THROUGH HOLE DC/DC CONVERTER, RAILWAY, DIP, 4:1, 40 W, 1 OUTPUT, 12 V

Deep-Dive with AI

Search across all available documentation for this part.

RP40-FR
Power Supplies - Board Mount

RP40-4812SFR/N-HC

Active
Recom Power

ISOLATED THROUGH HOLE DC/DC CONVERTER, RAILWAY, DIP, 4:1, 40 W, 1 OUTPUT, 12 V

Deep-Dive with AI

Technical Specifications

Parameters and characteristics for this part

SpecificationRP40-4812SFR/N-HC
ApplicationsRailway, ITE (Commercial)
Control FeaturesActive Low, Enable
Current - Output (Max) [Max]3.333 A
Efficiency92 %
FeaturesOTP, UVLO, OVP, SCP, Remote On/Off, OCP
Mounting TypeThrough Hole
Number of Outputs1
Operating Temperature [Max]105 C
Operating Temperature [Min]-40 °C
Package / Case6-DIP Module
Power (Watts)40 W
Size / Dimension [x]56.8 mm
Size / Dimension [x]2.24 in
Size / Dimension [y]1 "
Size / Dimension [y]25.4 mm
Size / Dimension [z]0.66 in
Size / Dimension [z]16.8 mm
Supplier Device Package6-DIP Module
TypeIsolated Module
Voltage - Input (Max) [Max]75 V
Voltage - Input (Min) [Min]18 V
Voltage - Isolation1.6 kV
Voltage - Output 112 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyN/A 0$ 110.82
Tray 20$ 112.39
NewarkEach 10$ 131.38
25$ 122.76
50$ 118.46
100$ 114.15

Description

General part information

RP40-4812 Series

The RP40-4812SFR/N-HC from Recom Power is a 40W, 2" x 1" regulated single output DC to DC converter. This DC to DC converter is especially designed for railway applications. It has wide 4:1 input voltage range, six sided continuous shield, 30mAp-p input reflected ripple current, 60ms (power-up) and 60ms (remote ON/OFF) start-up time. Internal operating frequency is 250KHz and output voltage accuracy is ±1%. It is certified by UL60950-1 AM2, CE, cRJus E196683, CSA C22.2 number 60950-1-07 and EN50155 standards. The device also features continuous, automatic recovery short circuit protection (SCP), overvoltage protection, overload protection and overtemperature protection. The converter has minimum isolation resistance of 1Gohm at 500VDC, maximum isolation capacitance of 1500pF, line voltage regulation of ±0.2% (low line to high line at full load) and transient response recovery time of 250μs. It is made of copper alloy (CuZn33) case, FR4 PCB base and silicone (UL94V-0) potting.

Documents