Parameters and characteristics for this part

SpecificationMAX6466XR22+T
Mounting TypeSurface Mount
Number of Voltages Monitored1
Operating Temperature [Max]125 °C
Operating Temperature [Min]-40 °C
OutputOpen Drain or Open Collector
Package / CaseSOT-323, SC-70
ResetActive Low
Reset Timeout [Min]150 ms
Supplier Device PackageSC-70-3
TypeSimple Reset/Power-On Reset
Voltage - Threshold2.2 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyCut Tape (CT) 1$ 9.23
10$ 6.38
25$ 5.65
100$ 4.83
250$ 4.43
500$ 4.18
1000$ 3.98
Digi-Reel® 1$ 9.23
10$ 6.38
25$ 5.65
100$ 4.83
250$ 4.43
500$ 4.18
1000$ 3.98
N/A 1391$ 4.59
Tape & Reel (TR) 2500$ 2.35

Description

General part information

MAX6466 Series

The MAX6461-MAX6466 family of ultra-low-power voltage detectors and µP reset supervisory circuits monitors battery, power-supply, and system voltages. Each circuit includes a precision bandgap reference, a comparator, internally trimmed resistor networks that set specified trip thresholds, and an internal 5% threshold hysteresis circuit (see theFunctional Diagram). Output is asserted when VCCfalls below the internal VTH- and remains asserted until VCCrises above VTH+ (VTH+ = VTH- x 1.05). These devices provide excellent circuit reliability and low cost by eliminating external components and adjustments when monitoring nominal system voltages from +1.6V to +5.5V. The MAX6461/MAX6462/MAX6463 are voltage detectors with a propagation delay of 17µs.The MAX6464/MAX6465/MAX6466 are µP supervisory circuits with a minimum reset timeout period of 150ms. All devices are available with thresholds from +1.6V to +5.5V in 100mV increments.The family is available with three output stage options: push-pull with active-low output, push-pull with active-high output, and open drain with active-low output. These devices are available in SC70 and SOT23 packages specified over the -40°C to +125°C temperature range.ApplicationsCell PhonesCordless PhonesLoad Switching/Power SequencingNoise-Immune µP Reset CircuitsPDAsPortable Battery-Powered EquipmentPortable Medical DevicesPower-Supply Monitoring in Digital/Analog SystemsPrecision Battery Monitoring