LTC4251-1IS6#TRMPBF
ActiveNEGATIVE VOLTAGE HOT SWAP CONTROLLERS IN SOT-23
Deep-Dive with AI
Search across all available documentation for this part.

LTC4251-1IS6#TRMPBF
ActiveNEGATIVE VOLTAGE HOT SWAP CONTROLLERS IN SOT-23
Deep-Dive with AI
Technical Specifications
Parameters and characteristics for this part
| Specification | LTC4251-1IS6#TRMPBF |
|---|---|
| Applications | -48 V |
| Current - Supply | 800 çA |
| Features | Latched Fault |
| Internal Switch(s) | False |
| Mounting Type | Surface Mount |
| Number of Channels [custom] | 1 |
| Operating Temperature [Max] | 85 °C |
| Operating Temperature [Min] | -40 C |
| Package / Case | SOT-23-6 Thin, TSOT-23-6 |
| Programmable Features | Circuit Breaker, UVLO, OVP, Current Limit, Fault Timeout |
| Supplier Device Package | TSOT-23-6 |
| Type | Hot Swap Controller |
| Voltage - Supply [Max] | -36 V |
| Voltage - Supply [Min] | -72 V |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
| Distributor | Package | Quantity | $ | Updated |
|---|---|---|---|---|
| Digikey | N/A | 0 | $ 3.40 | 1m+ |
Description
General part information
LTC4251 Series
The LTC4251/LTC4251-1/LTC4251-2 negative voltage Hot Swap™controllers allow a board to be safely inserted and removed from a live backplane. Output current is controlled by three stages of current limiting: a timed circuit breaker, active current limiting and a fast feed forward path that limits peak current under worst-case catastrophic fault conditions.Programmable undervoltage and overvoltage detectors disconnect the load whenever the input supply exceeds the desired operating range. The supply input is shunt regulated, allowing safe operation with very high supply voltages. A multifunction timer delays initial start-up and controls the circuit breaker’s response time.The LTC4251 UV/OV thresholds are designed to match the standard telecom operating range of –43V to –75V. The LTC4251-1 UV/OV thresholds extend the operating range to encompass –36V to –72V. The LTC4251-2 implements a UV threshold of –43V only.UV/OVLTC4251-43V / -75VLTC4251-1-36V / -72VLTC4251-2-43V UV OnlyLTC4251B-43V / -75VLTC4251B-1-36V / -72VLTC4251B-2-43V UV OnlyApplicationsHot Board InsertionElectronic Circuit Breaker–48V Distributed Power SystemsNegative Power Supply ControlCentral Office SwitchingProgrammable Current Limiting CircuitHigh Availability ServersDisk Arrays
Documents