Zenode.ai Logo
Beta
LMP91200EVAL/NOPB
Development Boards, Kits, Programmers

LMP91200EVAL/NOPB

Active
Texas Instruments

BOARD EVAL FOR LMP91200

Deep-Dive with AI

Search across all available documentation for this part.

DocumentsDatasheet
LMP91200EVAL/NOPB
Development Boards, Kits, Programmers

LMP91200EVAL/NOPB

Active
Texas Instruments

BOARD EVAL FOR LMP91200

Deep-Dive with AI

DocumentsDatasheet

Technical Specifications

Parameters and characteristics for this part

SpecificationLMP91200EVAL/NOPB
FunctionAnalog Front End (AFE)
Secondary AttributesSPI Interface(s)
Supplied ContentsBoard(s)
TypeInterface
Utilized IC / PartLMP91200

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$

Description

General part information

LMP91200 Series

The LMP91200 device is a sensor AFE for use in low-power, analytical-sensing applications. The LMP91200 is designed for 2-electrode sensors. This device provides all of the functionality needed to detect changes based on a delta voltage at the sensor. Optimized for low-power applications, the LMP91200 works over a voltage range of 1.8 V to 5.5 V. With its extremely low input bias current it is optimized for use with pH sensors. Also, in absence of supply voltage the very low input bias current reduces degradation of the pH probe when connected to the LMP91200. Two guard pins provide support for high parasitic impedance wiring. Depending on the configuration, total current consumption for the device is 50 µA while measuring pH. Available in a 16-pin TSSOP package, the LMP91200 operates from –40°C to +125°C.

The LMP91200 device is a sensor AFE for use in low-power, analytical-sensing applications. The LMP91200 is designed for 2-electrode sensors. This device provides all of the functionality needed to detect changes based on a delta voltage at the sensor. Optimized for low-power applications, the LMP91200 works over a voltage range of 1.8 V to 5.5 V. With its extremely low input bias current it is optimized for use with pH sensors. Also, in absence of supply voltage the very low input bias current reduces degradation of the pH probe when connected to the LMP91200. Two guard pins provide support for high parasitic impedance wiring. Depending on the configuration, total current consumption for the device is 50 µA while measuring pH. Available in a 16-pin TSSOP package, the LMP91200 operates from –40°C to +125°C.

Documents

Technical documentation and resources