L
Littelfuse/Commercial Vehicle Products
| Series | Category | # Parts | Status | Description |
|---|---|---|---|---|
| Part | Spec A | Spec B | Spec C | Spec D | Description |
|---|---|---|---|---|---|
| Series | Category | # Parts | Status | Description |
|---|---|---|---|---|
| Part | Spec A | Spec B | Spec C | Spec D | Description |
|---|---|---|---|---|---|
| Part | Category | Description |
|---|---|---|
Littelfuse/Commercial Vehicle Products DRR-DTH-Q2167-2Obsolete | Switches | SWITCH REED CUSTOM |
Littelfuse/Commercial Vehicle Products | Switches | ROCKER SWITCHES |
Littelfuse/Commercial Vehicle Products 0HEV040.ZXPCBLObsolete | Circuit Protection | FUSE - HEV LC 425VDC 40A, PCB 3.9MM TERM/ BULK |
Littelfuse/Commercial Vehicle Products | Switches | SWITCH TOGGLE 3PDT 5A 120V |
Littelfuse/Commercial Vehicle Products | Connectors Interconnects | LINEAR IC'S |
Littelfuse/Commercial Vehicle Products | Circuit Protection | VARISTOR, 243V, 215J, THROUGH HOLE MOUNT, RADIAL LEADED, HALOGEN FREE AND ROHS COMPLIANT |
Littelfuse/Commercial Vehicle Products 7201K9ALEObsolete | Switches | SWITCH TOGGLE DPDT 5A 120V |
Littelfuse/Commercial Vehicle Products | Circuit Protection | FUS 600V T/D CLS RK1 4-1/2A INDICATOR P |
Littelfuse/Commercial Vehicle Products | Connectors Interconnects | LINEAR IC'S |
Littelfuse/Commercial Vehicle Products | Circuit Protection | THERMALLY PROTECTED VARISTOR 14MM ROHS/ BULK |
| Series | Category | # Parts | Status | Description |
|---|---|---|---|---|
JLLS1100PFUS 600V F/A CLASS T 1100A PLTD | Circuit Protection | 1 | Active | Space-saving Class T fuses are the most compact fuses available in ratings above 30 amperes — less than one-third the size of comparable Class R fuses. When rated in accordance with the NEC, Class T fuses provide fast-acting overload and short circuit protection for non-inductive circuits and equipment. Used in inductive circuits, the ampere rating of Class T fuses must be increased to prevent opening on inrush currents. In such instances, Class T fuses may provide only short circuit protection. For motor and general purpose circuits where space is not critical, we recommend POWR-PRO™ JTD_ID Indicator series, LLNRK/LLSRK series, or FLSR_ID Indicator series.Space Saving: Typical three-pole Class T fuse blocks require less than 50% of the panel area required for Class R fuse blocks. Switch enclosures, fuse pullouts, and other equipment using Class T fuses are often correspondingly more compact. Safety: 200,000 A.I.R. — Reliable interruption of all overcurrents up to 200,000 amperes. Extremely current limiting — Stops damaging short circuit current faster than any mechanical protective device. Fast-Acting — Provides fast-acting overload protection to equipment such as variable speed drives, rectifiers and other equipment containing surge-sensitive components. Longer Equipment Life: Current limiting design greatly reduces damage to equipment caused by heating and magnetic effects of short circuit currents. Economical: Extremely current limiting design often permits use of readily available, less costly equipment. Used as input or output fuses for surge-sensitive components, such as variable speed drives and rectifiers, fast-acting Class T JLLS fuses may prevent opening of expensive semiconductor fuses protecting individual components. |
JLLS110PFUS 600V F/A CLASS T 110A PLTD | Circuit Protection | 1 | Active | Space-saving Class T fuses are the most compact fuses available in ratings above 30 amperes — less than one-third the size of comparable Class R fuses. When rated in accordance with the NEC, Class T fuses provide fast-acting overload and short circuit protection for non-inductive circuits and equipment. Used in inductive circuits, the ampere rating of Class T fuses must be increased to prevent opening on inrush currents. In such instances, Class T fuses may provide only short circuit protection. For motor and general purpose circuits where space is not critical, we recommend POWR-PRO™ JTD_ID Indicator series, LLNRK/LLSRK series, or FLSR_ID Indicator series.Space Saving: Typical three-pole Class T fuse blocks require less than 50% of the panel area required for Class R fuse blocks. Switch enclosures, fuse pullouts, and other equipment using Class T fuses are often correspondingly more compact. Safety: 200,000 A.I.R. — Reliable interruption of all overcurrents up to 200,000 amperes. Extremely current limiting — Stops damaging short circuit current faster than any mechanical protective device. Fast-Acting — Provides fast-acting overload protection to equipment such as variable speed drives, rectifiers and other equipment containing surge-sensitive components. Longer Equipment Life: Current limiting design greatly reduces damage to equipment caused by heating and magnetic effects of short circuit currents. Economical: Extremely current limiting design often permits use of readily available, less costly equipment. Used as input or output fuses for surge-sensitive components, such as variable speed drives and rectifiers, fast-acting Class T JLLS fuses may prevent opening of expensive semiconductor fuses protecting individual components. |
JLLS1200FUS 600V F/A CLASS T 1200A | Electrical, Specialty Fuses | 1 | Active | JLLS1200 is a Class T fuse with an ampere rating of 1200 and knife-blade-style construction. |
JLLS150FUS 600V F/A CLASS T 150A | Electrical, Specialty Fuses | 1 | Active | JLLS150 is a Class T fuse with an ampere rating of 150 and knife-blade-style construction. |
JLLS200FUS 600V F/A CLASS T 200A | Circuit Protection | 1 | Active | JLLS200 is a Class T fuse with an ampere rating of 200 and knife-blade-style construction. |
JLLS225FUS 600V F/A CLASS T 225A | Circuit Protection | 1 | Active | JLLS225 is a Class T fuse with an ampere rating of 225 and knife-blade-style construction. |
JLLS250PFUS 600V F/A CLASS T 250A PLTD | Circuit Protection | 1 | Active | Space-saving Class T fuses are the most compact fuses available in ratings above 30 amperes — less than one-third the size of comparable Class R fuses. When rated in accordance with the NEC, Class T fuses provide fast-acting overload and short circuit protection for non-inductive circuits and equipment. Used in inductive circuits, the ampere rating of Class T fuses must be increased to prevent opening on inrush currents. In such instances, Class T fuses may provide only short circuit protection. For motor and general purpose circuits where space is not critical, we recommend POWR-PRO™ JTD_ID Indicator series, LLNRK/LLSRK series, or FLSR_ID Indicator series.Space Saving: Typical three-pole Class T fuse blocks require less than 50% of the panel area required for Class R fuse blocks. Switch enclosures, fuse pullouts, and other equipment using Class T fuses are often correspondingly more compact. Safety: 200,000 A.I.R. — Reliable interruption of all overcurrents up to 200,000 amperes. Extremely current limiting — Stops damaging short circuit current faster than any mechanical protective device. Fast-Acting — Provides fast-acting overload protection to equipment such as variable speed drives, rectifiers and other equipment containing surge-sensitive components. Longer Equipment Life: Current limiting design greatly reduces damage to equipment caused by heating and magnetic effects of short circuit currents. Economical: Extremely current limiting design often permits use of readily available, less costly equipment. Used as input or output fuses for surge-sensitive components, such as variable speed drives and rectifiers, fast-acting Class T JLLS fuses may prevent opening of expensive semiconductor fuses protecting individual components. |
JLLS300PFUS 600V F/A CLASS T 300A PLTD | Circuit Protection | 1 | Active | Space-saving Class T fuses are the most compact fuses available in ratings above 30 amperes — less than one-third the size of comparable Class R fuses. When rated in accordance with the NEC, Class T fuses provide fast-acting overload and short circuit protection for non-inductive circuits and equipment. Used in inductive circuits, the ampere rating of Class T fuses must be increased to prevent opening on inrush currents. In such instances, Class T fuses may provide only short circuit protection. For motor and general purpose circuits where space is not critical, we recommend POWR-PRO™ JTD_ID Indicator series, LLNRK/LLSRK series, or FLSR_ID Indicator series.Space Saving: Typical three-pole Class T fuse blocks require less than 50% of the panel area required for Class R fuse blocks. Switch enclosures, fuse pullouts, and other equipment using Class T fuses are often correspondingly more compact. Safety: 200,000 A.I.R. — Reliable interruption of all overcurrents up to 200,000 amperes. Extremely current limiting — Stops damaging short circuit current faster than any mechanical protective device. Fast-Acting — Provides fast-acting overload protection to equipment such as variable speed drives, rectifiers and other equipment containing surge-sensitive components. Longer Equipment Life: Current limiting design greatly reduces damage to equipment caused by heating and magnetic effects of short circuit currents. Economical: Extremely current limiting design often permits use of readily available, less costly equipment. Used as input or output fuses for surge-sensitive components, such as variable speed drives and rectifiers, fast-acting Class T JLLS fuses may prevent opening of expensive semiconductor fuses protecting individual components. |
JLLS350FUS 600V F/A CLASS T 350A | Circuit Protection | 1 | Active | JLLS350 is a Class T fuse with an ampere rating of 350 and knife-blade-style construction. |
JLLS400FUS 600V F/A CLASS T 400A | Electrical, Specialty Fuses | 1 | Active | JLLS400 is a Class T fuse with an ampere rating of 400 and knife-blade-style construction. |