L
LITTELFUSE
| Series | Category | # Parts | Status | Description |
|---|---|---|---|---|
| Part | Spec A | Spec B | Spec C | Spec D | Description |
|---|---|---|---|---|---|
| Series | Category | # Parts | Status | Description |
|---|---|---|---|---|
| Part | Spec A | Spec B | Spec C | Spec D | Description |
|---|---|---|---|---|---|
| Part | Category | Description |
|---|---|---|
LITTELFUSE DRR-DTH-Q2167-2Obsolete | Switches | SWITCH REED CUSTOM |
LITTELFUSE DRR-DTH-70-85Obsolete | Switches | SWITCH REED SPDT 350MA 350V |
LITTELFUSE | Switches | ROCKER SWITCHES |
LITTELFUSE | Switches | SWITCH PUSHBUTTON DPDT 6A 250V |
LITTELFUSE 0HEV040.ZXPCBLObsolete | Circuit Protection | FUSE - HEV LC 425VDC 40A, PCB 3.9MM TERM/ BULK |
LITTELFUSE 0324015.HObsolete | Circuit Protection | FUSE CERM 15A 250VAC 125VDC 3AB |
LITTELFUSE NANOSMD200LR-2Obsolete | Circuit Protection | PTC RESET FUSE 6V 2A 1206 |
LITTELFUSE | Connectors Interconnects | LINEAR IC'S |
LITTELFUSE | Circuit Protection | TVS 1.5KW 36V 5%BI DO-214AB TR13 |
LITTELFUSE | Connectors Interconnects | LINEAR IC'S |
| Series | Category | # Parts | Status | Description |
|---|---|---|---|---|
THD1B410.5SDELAY ON MAKE TIMER | Industrial Automation and Controls | 1 | Active | The THD1 Series combines accurate timing circuitry with high power solid-state switching. It can switch motors, lamps, and heaters directly without a contactor. You can reduce labor, component cost, and increase reliability with these small, easy-to-use timers. Operation (Delay-on-Make) Upon application of input voltage, the time delay begins. The output is de-energized before and during the time delay. At the end of the time delay, the output energizes and remains energized until input voltage is removed.Reset: Removing input voltage resets the time delay and output. |
THD2CINTERVAL TIMER | Time Delay Relays | 4 | Active | The THD2 Series combines accurate timing circuitry with high power solid-state switching. It can switch motors, lamps, and heaters directly without a contactor. You can reduce labor, component cost, and increase reliability with these small, easy-to-use THD2 Series timers. Operation (Interval) Upon application of input voltage, the time delay begins. The output energizes during the time delay. At the end of the time delay, the output de-energizes and remains de-energized until input voltage is removed.Reset: Removing input voltage resets the time delay and the output. |
THD2C423INTERVAL TIMER | Industrial Automation and Controls | 1 | Active | The THD2 Series combines accurate timing circuitry with high power solid-state switching. It can switch motors, lamps, and heaters directly without a contactor. You can reduce labor, component cost, and increase reliability with these small, easy-to-use THD2 Series timers. Operation (Interval) Upon application of input voltage, the time delay begins. The output energizes during the time delay. At the end of the time delay, the output de-energizes and remains de-energized until input voltage is removed.Reset: Removing input voltage resets the time delay and the output. |
| Industrial Automation and Controls | 1 | Active | ||
| Industrial Automation and Controls | 1 | Active | ||
THDB421ADIGI-POWER (D.O.B.) | Industrial Automation and Controls | 1 | Active | The THDB Series combines accurate timing circuitry with high power, solid-state switching. It can switch motors, lamps, and heaters directly without a contactor. You can reduce labor, component cost, and increase reliability with these small, easy-to-use, THDB Series timers. Operation (Delay-on-Break) Input voltage must be applied before and during timing. Upon closure of the initiate switch, the output energizes. The time delay begins when the initiate switch is opened. The output remains energized during timing. At the end of the time delay, the output de-energizes. The output energizes if the initiate switch is closed when input voltage is applied.Reset: Reclosing the initiate switch during timing resets the time delay. Loss of input voltage resets the time delay and output. |
THDS4DIGI-POWER (SINGLE SHOT) | Time Delay Relays | 2 | Active | The THDS Series combines accurate timing circuitry with high power solid-state switching. It can switch motors, lamps, and heaters directly without a contactor. You can reduce labor, component cost, and increase reliability with these small, easy-to-use THDS Series timers. Operation (Single Shot) Input voltage must be applied before and during timing. Upon momentary or maintained closure of the initiate switch, the output energizes for a measured interval of time. At the end of the delay, the output de-energizes. Opening or reclosing the initiate switch during timing has no affect on the time delay. The output energizes if the initiate switch is closed when input voltage is applied.Reset: Reset occurs when the time delay is complete and the initiate switch is opened. Loss of input voltage resets the time delay and output. |
THDS610.25SADIGI-POWER (SINGLE SHOT) | Industrial Automation and Controls | 1 | Active | The THDS Series combines accurate timing circuitry with high power solid-state switching. It can switch motors, lamps, and heaters directly without a contactor. You can reduce labor, component cost, and increase reliability with these small, easy-to-use THDS Series timers. Operation (Single Shot) Input voltage must be applied before and during timing. Upon momentary or maintained closure of the initiate switch, the output energizes for a measured interval of time. At the end of the delay, the output de-energizes. Opening or reclosing the initiate switch during timing has no affect on the time delay. The output energizes if the initiate switch is closed when input voltage is applied.Reset: Reset occurs when the time delay is complete and the initiate switch is opened. Loss of input voltage resets the time delay and output. |
THS422BPOWER (SINGLE SHOT TIMER) | Industrial Automation and Controls | 1 | Active | The TH series is a solid-state relay and timer combined into one compact, easy-to-use control. When mounted to a metal surface, the TH Series may be used to directly control lamp or heater loads of up to 20A steady, 200A inrush. Its single shot function can perform dispensing and pulse shaping operations. The initiate switch can be a momentary or maintained type of switch. Time delays can be selected from 0.1 - 600 seconds in 4 ranges. The THC Series is used for coin vending applications where fast initiate response is required. Operation (Single Shot) Input voltage must be applied before and during timing. Upon momentary or maintained closure of the initiate switch (leading edge triggered), the output energizes for a measured interval of time. At the end of the delay, the output de-energizes. Opening or reclosing the initiate switch during timing has no affect on the time delay. The output will energize if the initiate switch is closed when input voltage is applied.Reset: Reset occurs when the time delay is complete and the initiate switch opens. Loss of input voltage resets the time delay and output. |
THS422CPOWER (SINGLE SHOT TIMER) | Industrial Automation and Controls | 1 | Active | The TH series is a solid-state relay and timer combined into one compact, easy-to-use control. When mounted to a metal surface, the TH Series may be used to directly control lamp or heater loads of up to 20A steady, 200A inrush. Its single shot function can perform dispensing and pulse shaping operations. The initiate switch can be a momentary or maintained type of switch. Time delays can be selected from 0.1 - 600 seconds in 4 ranges. The THC Series is used for coin vending applications where fast initiate response is required. Operation (Single Shot) Input voltage must be applied before and during timing. Upon momentary or maintained closure of the initiate switch (leading edge triggered), the output energizes for a measured interval of time. At the end of the delay, the output de-energizes. Opening or reclosing the initiate switch during timing has no affect on the time delay. The output will energize if the initiate switch is closed when input voltage is applied.Reset: Reset occurs when the time delay is complete and the initiate switch opens. Loss of input voltage resets the time delay and output. |