TPS3808-Q1 Series
Enhanced Product Low Quiescent Current, Programmable Delay Supervisory Circuit
Manufacturer: Texas Instruments
Catalog
Enhanced Product Low Quiescent Current, Programmable Delay Supervisory Circuit
| Part | Output | Number of Voltages Monitored | Voltage - Threshold | Operating Temperature [Min] | Operating Temperature [Max] | Reset | Reset Timeout | Mounting Type | Supplier Device Package | Type | Voltage - Threshold | Package / Case |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Texas Instruments | Open Drain or Open Collector | 1 | Adjustable/Selectable | -40 °C | 125 ¯C | Active Low | Adjustable/Selectable | Surface Mount | 6-WSON (2x2) | Simple Reset/Power-On Reset | ||
Texas Instruments | Open Drain or Open Collector | 1 | -40 °C | 125 ¯C | Active Low | Adjustable/Selectable | Surface Mount | SOT-23-6 | Simple Reset/Power-On Reset | 2.79 V | SOT-23-6 | |
Texas Instruments | Open Drain or Open Collector | 1 | -40 °C | 125 ¯C | Active Low | Adjustable/Selectable | Surface Mount | SOT-23-6 | Simple Reset/Power-On Reset | 1.12 V | SOT-23-6 | |
Texas Instruments | Open Drain or Open Collector | 1 | -40 °C | 125 ¯C | Active Low | Adjustable/Selectable | Surface Mount | SOT-23-6 | Simple Reset/Power-On Reset | 1.67 V | SOT-23-6 | |
Texas Instruments | Open Drain or Open Collector | 1 | -40 °C | 125 ¯C | Active Low | Adjustable/Selectable | Surface Mount | SOT-23-6 | Simple Reset/Power-On Reset | 3.07 V | SOT-23-6 | |
Texas Instruments | Open Drain or Open Collector | 1 | Adjustable/Selectable | -40 °C | 125 ¯C | Active Low | Adjustable/Selectable | Surface Mount | SOT-23-6 | Simple Reset/Power-On Reset | SOT-23-6 | |
Texas Instruments | Open Drain or Open Collector | 1 | -40 °C | 125 ¯C | Active Low | Adjustable/Selectable | Surface Mount | SOT-23-6 | Simple Reset/Power-On Reset | SOT-23-6 | ||
Texas Instruments | Open Drain or Open Collector | 1 | -55 °C | 125 ¯C | Active Low | Adjustable/Selectable | Surface Mount | SOT-23-6 | Simple Reset/Power-On Reset | 3.07 V | SOT-23-6 | |
Texas Instruments | Open Drain or Open Collector | 1 | -40 °C | 125 ¯C | Active Low | Adjustable/Selectable | Surface Mount | SOT-23-6 | Simple Reset/Power-On Reset | 2.33 V | SOT-23-6 | |
Texas Instruments | Open Drain or Open Collector | 1 | -40 °C | 125 ¯C | Active Low | Adjustable/Selectable | Surface Mount | 6-WSON (2x2) | Simple Reset/Power-On Reset | 2.79 V |
Key Features
• Controlled BaselineOne Assembly SiteOne Test SiteOne Fabrication SiteExtended Temperature Performance of–55°C to 125°CEnhanced Diminishing Manufacturing Sources(DMS) SupportEnhanced Product-Change NotificationQualification Pedigree1Power-On Reset Generator With AdjustableDelay Time: 1.25 ms to 10 sVery Low Quiescent Current: 2.4 µA TypicalHigh Threshold Accuracy: 0.5% TypicalFixed Threshold Voltages for Standard VoltageRails From 0.9 V to 5 V and Adjustable VoltageDown to 0.4 V Are AvailableManual Reset (MR) InputOpen-DrainRESETOutputTemperature Range: –55°C to 125°CSmall SOT-23 PackageControlled BaselineOne Assembly SiteOne Test SiteOne Fabrication SiteExtended Temperature Performance of–55°C to 125°CEnhanced Diminishing Manufacturing Sources(DMS) SupportEnhanced Product-Change NotificationQualification Pedigree1Power-On Reset Generator With AdjustableDelay Time: 1.25 ms to 10 sVery Low Quiescent Current: 2.4 µA TypicalHigh Threshold Accuracy: 0.5% TypicalFixed Threshold Voltages for Standard VoltageRails From 0.9 V to 5 V and Adjustable VoltageDown to 0.4 V Are AvailableManual Reset (MR) InputOpen-DrainRESETOutputTemperature Range: –55°C to 125°CSmall SOT-23 Package
Description
AI
The TPS3808Gxx-Q1 microprocessor supervisory circuits monitor system voltages from 0.4 V to 5 V, asserting an open-drainRESETsignal when the SENSE voltage drops below a preset threshold or when the manual reset (MR) pin drops to a logic low. TheRESEToutput remains low for the user-adjustable delay time after the SENSE voltage andMRreturn above their thresholds.
The TPS3808Gxx-Q1 device uses a precision reference to achieve 0.5% threshold accuracy for VIT≤ 3.3 V. The reset delay time can be set to 20 ms by disconnecting the CTpin, 300 ms by connecting the CTpin to VDDusing a resistor, or can be user-adjusted from 1.25 ms to 10 s by connecting the CTpin to an external capacitor. The TPS3808Gxx-Q1 has a very low typical quiescent current of 2.4 µA, so it is well suited for battery-powered applications. The device is available in a small SOT-23 package (one option available in WSON) and is fully specified over a temperature range of –40°C to +125°C (TJ).
For more information about TI’s voltage supervisor portfolio, visit theSupervisor and Reset IC Overview Pagepage.
The TPS3808Gxx-Q1 microprocessor supervisory circuits monitor system voltages from 0.4 V to 5 V, asserting an open-drainRESETsignal when the SENSE voltage drops below a preset threshold or when the manual reset (MR) pin drops to a logic low. TheRESEToutput remains low for the user-adjustable delay time after the SENSE voltage andMRreturn above their thresholds.
The TPS3808Gxx-Q1 device uses a precision reference to achieve 0.5% threshold accuracy for VIT≤ 3.3 V. The reset delay time can be set to 20 ms by disconnecting the CTpin, 300 ms by connecting the CTpin to VDDusing a resistor, or can be user-adjusted from 1.25 ms to 10 s by connecting the CTpin to an external capacitor. The TPS3808Gxx-Q1 has a very low typical quiescent current of 2.4 µA, so it is well suited for battery-powered applications. The device is available in a small SOT-23 package (one option available in WSON) and is fully specified over a temperature range of –40°C to +125°C (TJ).
For more information about TI’s voltage supervisor portfolio, visit theSupervisor and Reset IC Overview Pagepage.