MWLT40 Series
Manufacturer: Bel Fuse Inc.
AC/DC CONVERTER 24V 41W
| Part | Size / Dimension [y] | Size / Dimension [y] | Size / Dimension [z] | Size / Dimension [z] | Size / Dimension [x] | Size / Dimension [x] | Current - Output 1 | Voltage - Output 1 | Features | Approval Agency | Applications | Voltage - Isolation | Number of Outputs | Power (Watts) | Standard Number | Mounting Type | Type | Voltage - Input [Max] | Voltage - Input [Min] | Operating Temperature [Max] | Operating Temperature [Min] | Efficiency | Voltage - Output 2 | Current - Output 2 | Voltage - Output 3 | Current - Output 3 | Minimum Load Required |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bel Fuse Inc. | 50.8 mm | 2 in | 1.12 " | 28.5 mm | 101.6 mm | 4 " | 1.7 A | 24 V | Adjustable Output Universal Input | CE cUL NEMKO UL | Medical | 5.7 kV | 1 | 41 W | 60601-1 | Chassis Mount | Open Frame | 264 VAC | 90 VAC | 70 °C | -20 °C | 85 % | |||||
Bel Fuse Inc. | 50.8 mm | 2 in | 1.2 " | 30.5 mm | 101.6 mm | 4 " | 6 A | 5.2 V | Adjustable Output Universal Input | CE cUL NEMKO UL | Medical | 5.7 kV | 3 | 62 W | 60601-1 | Chassis Mount | Open Frame | 264 VAC | 90 VAC | 70 °C | -20 °C | 85 % | 24 V | 1 A | -12.8 V | 500 mA | |
Bel Fuse Inc. | 50.8 mm | 2 in | 1.2 " | 30.5 mm | 101.6 mm | 4 " | 6 A | 5.2 V | Adjustable Output Universal Input | CE cUL NEMKO UL | Medical | 5.7 kV | 3 | 63 W | 60601-1 | Chassis Mount | Open Frame | 264 VAC | 90 VAC | 70 °C | -20 °C | 85 % | 12.5 V | 2 A | -12.8 V | 500 mA | |
Bel Fuse Inc. | 50.8 mm | 2 in | 1.12 " | 28.5 mm | 101.6 mm | 4 " | 8 A | 5.1 V | Adjustable Output Universal Input | CE cUL NEMKO UL | Medical | 5.7 kV | 1 | 41 W | 60601-1 | Chassis Mount | Open Frame | 264 VAC | 90 VAC | 70 °C | -20 °C | 85 % | |||||
Bel Fuse Inc. | 50.8 mm | 2 in | 1.12 " | 28.5 mm | 101.6 mm | 4 " | 830 mA | 48 V | Adjustable Output Universal Input | CE cUL NEMKO UL | Medical | 5.7 kV | 1 | 40 W | 60601-1 | Chassis Mount | Open Frame | 264 VAC | 90 VAC | 70 °C | -20 °C | 85 % | |||||
Bel Fuse Inc. | 50.8 mm | 2 in | 1.2 " | 30.5 mm | 101.6 mm | 4 " | 6 A | 5.2 V | Adjustable Output Universal Input | CE cUL NEMKO UL | Medical | 5.7 kV | 3 | 63 W | 60601-1 | Chassis Mount | Open Frame | 264 VAC | 90 VAC | 70 °C | -20 °C | 85 % | 12.5 V | 2 A | -12.8 V | 500 mA | |
Bel Fuse Inc. | 50.8 mm | 2 in | 1.12 " | 28.5 mm | 101.6 mm | 4 " | 2.7 A | 15 V | Adjustable Output Universal Input | CE cUL NEMKO UL | Medical | 5.7 kV | 1 | 41 W | 60601-1 | Chassis Mount | Open Frame | 264 VAC | 90 VAC | 70 °C | -20 °C | 85 % | |||||
Bel Fuse Inc. | 50.8 mm | 2 in | 1.12 " | 28.5 mm | 101.6 mm | 4 " | 3.5 A | 12 V | Adjustable Output Universal Input | CE cUL NEMKO UL | Medical | 5.7 kV | 1 | 42 W | 60601-1 | Chassis Mount | Open Frame | 264 VAC | 90 VAC | 70 °C | -20 °C | 85 % | |||||
Bel Fuse Inc. | 50.8 mm | 2 in | 1.2 " | 30.5 mm | 101.6 mm | 4 " | 6 A | 5.2 V | Adjustable Output Universal Input | CE cUL NEMKO UL | Medical | 5.7 kV | 3 | 61 W | 60601-1 | Chassis Mount | Open Frame | 264 VAC | 90 VAC | 70 °C | -20 °C | 85 % | 14.6 V | 1.5 A | -14.8 V | 500 mA | |
Bel Fuse Inc. | 50.8 mm | 2 in | 1.2 " | 30.5 mm | 101.6 mm | 4 " | 6 A | 3.3 V | Adjustable Output Universal Input | CE cUL NEMKO UL | Medical | 5.7 kV | 3 | 42 W | 60601-1 | Chassis Mount | Open Frame | 264 VAC | 90 VAC | 70 °C | -20 °C | 85 % | 5.2 V | 3 A | -12.8 V | 500 mA |