MWLT60 Series
Manufacturer: Bel Fuse Inc.
AC/DC CNVRTR 5.2V 24V -12.8V 84W
| Part | Applications | Current - Output 1 | Approval Agency | Current - Output 2 | Voltage - Isolation | Voltage - Input [Max] | Voltage - Input [Min] | Features | Voltage - Output 3 | Voltage - Output 1 | Voltage - Output 2 | Current - Output 3 | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [x] | Size / Dimension [y] | Size / Dimension [x] | Size / Dimension [z] | Mounting Type | Efficiency | Power (Watts) | Operating Temperature [Max] | Operating Temperature [Min] | Number of Outputs | Type | Minimum Load Required |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bel Fuse Inc. | Medical | 8 A | CE cUL NEMKO UL | 1.5 A | 5.7 kV | 264 VAC | 90 VAC | Adjustable Output Universal Input | -12.8 V | 5.2 V | 24 V | 500 mA | 1.2 " | 50.8 mm | 101.6 mm | 2 in | 4 " | 30.5 mm | Chassis Mount | 85 % | 84 W | 70 °C | -20 °C | 3 | Open Frame | |
Bel Fuse Inc. | Medical | 8 A | CE cUL NEMKO UL | 3 A | 5.7 kV | 264 VAC | 90 VAC | Adjustable Output Universal Input | -12.8 V | 5.2 V | 12.5 V | 500 mA | 1.2 " | 50.8 mm | 101.6 mm | 2 in | 4 " | 30.5 mm | Chassis Mount | 85 % | 86 W | 70 °C | -20 °C | 3 | Open Frame | |
Bel Fuse Inc. | Medical | 6 A | CE cUL NEMKO UL | 3 A | 5.7 kV | 264 VAC | 90 VAC | Adjustable Output Universal Input | -12.8 V | 3.3 V | 5.2 V | 500 mA | 1.2 " | 50.8 mm | 101.6 mm | 2 in | 4 " | 30.5 mm | Chassis Mount | 85 % | 42 W | 70 °C | -20 °C | 3 | Open Frame | |
Bel Fuse Inc. | Medical | 4.33 A | CE cUL NEMKO UL | 5.7 kV | 264 VAC | 90 VAC | Adjustable Output Universal Input | 15 V | 1.12 " | 50.8 mm | 101.6 mm | 2 in | 4 " | 28.5 mm | Chassis Mount | 85 % | 70 °C | -20 °C | 1 | Open Frame | ||||||
Bel Fuse Inc. | Medical | 8 A | CE cUL NEMKO UL | 3 A | 5.7 kV | 264 VAC | 90 VAC | Adjustable Output Universal Input | -12.8 V | 5.2 V | 12.5 V | 500 mA | 1.2 " | 50.8 mm | 101.6 mm | 2 in | 4 " | 30.5 mm | Chassis Mount | 85 % | 86 W | 70 °C | -20 °C | 3 | Open Frame | |
Bel Fuse Inc. | Medical | 8 A | CE cUL NEMKO UL | 2.5 A | 5.7 kV | 264 VAC | 90 VAC | Adjustable Output Universal Input | -14.8 V | 5.2 V | 14.6 V | 500 mA | 1.2 " | 50.8 mm | 101.6 mm | 2 in | 4 " | 30.5 mm | Chassis Mount | 85 % | 86 W | 70 °C | -20 °C | 3 | Open Frame | |
Bel Fuse Inc. | Medical | 10 A | CE cUL NEMKO UL | 5.7 kV | 264 VAC | 90 VAC | Adjustable Output Universal Input | 5.1 V | 1.12 " | 50.8 mm | 101.6 mm | 2 in | 4 " | 28.5 mm | Chassis Mount | 85 % | 51 W | 70 °C | -20 °C | 1 | Open Frame | |||||
Bel Fuse Inc. | Medical | 4.33 A | CE cUL NEMKO UL | 5.7 kV | 264 VAC | 90 VAC | Adjustable Output Universal Input | 15 V | 1.12 " | 50.8 mm | 101.6 mm | 2 in | 4 " | 28.5 mm | Chassis Mount | 85 % | 70 °C | -20 °C | 1 | Open Frame | ||||||
Bel Fuse Inc. | Medical | 8 A | CE cUL NEMKO UL | 1.5 A | 5.7 kV | 264 VAC | 90 VAC | Adjustable Output Universal Input | -12.8 V | 5.2 V | 24 V | 500 mA | 1.2 " | 50.8 mm | 101.6 mm | 2 in | 4 " | 30.5 mm | Chassis Mount | 85 % | 84 W | 70 °C | -20 °C | 3 | Open Frame | |