
Catalog
Quad Differential Comparator
Key Features
• Wide Supply RangesSingle Supply: 2 V to 36 V(Tested to 30 V)Dual Supplies: ±1 V to ±18 V(Tested to ±15 V)Low Supply-Current Drain Independent ofSupply Voltage: 0.8 mA (Typical)Low Input Bias Current: 25 nA (Typical)Low Input Offset Voltage: 2 mV (Typical)Common-Mode Input Voltage RangeIncludes GroundDifferential Input Voltage Range Equal to Maximum-Rated Supply Voltage: ±36 VLow Output Saturation VoltageOutput Compatible With TTL, MOS, and CMOSOn Products Compliant to MIL-PRF-38535,All Parameters Are Tested Unless Otherwise Noted. On All Other Products, Production Processing Does Not Necessarily Include Testing of All Parameters.Wide Supply RangesSingle Supply: 2 V to 36 V(Tested to 30 V)Dual Supplies: ±1 V to ±18 V(Tested to ±15 V)Low Supply-Current Drain Independent ofSupply Voltage: 0.8 mA (Typical)Low Input Bias Current: 25 nA (Typical)Low Input Offset Voltage: 2 mV (Typical)Common-Mode Input Voltage RangeIncludes GroundDifferential Input Voltage Range Equal to Maximum-Rated Supply Voltage: ±36 VLow Output Saturation VoltageOutput Compatible With TTL, MOS, and CMOSOn Products Compliant to MIL-PRF-38535,All Parameters Are Tested Unless Otherwise Noted. On All Other Products, Production Processing Does Not Necessarily Include Testing of All Parameters.
Description
AI
The LM139A-MIL device consists of four independent voltage comparators that are designed to operate from a single power supply over a wide range of voltages. Operation from dual supplies also is possible, as long as the difference between the two supplies is 2 V to 36 V, and VCCis at least 1.5 V more positive than the input common-mode voltage. Current drain is independent of the supply voltage. The outputs can be connected to other open-collector outputs to achieve wired-AND relationships.
The LM139A-MIL device is characterized for operation over the full military temperature range of –55°C to +125°C.
The LM139A-MIL device consists of four independent voltage comparators that are designed to operate from a single power supply over a wide range of voltages. Operation from dual supplies also is possible, as long as the difference between the two supplies is 2 V to 36 V, and VCCis at least 1.5 V more positive than the input common-mode voltage. Current drain is independent of the supply voltage. The outputs can be connected to other open-collector outputs to achieve wired-AND relationships.
The LM139A-MIL device is characterized for operation over the full military temperature range of –55°C to +125°C.